D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
E. Junction Box Installation
If the box is being wired from the INSIDE of the appliance:
• Remove the screw attaching the junction box/receptacle to
the outer shell, rotate the junction box inward to disengage
it from the outer shell (see Figure 12.2).
• Pull the electrical wires from outside the appliance through
the opening into the valve compartment and secure wires
with a Romex connector. See Figure 12.2.
• Make all necessary wire connections to the junction box/
receptacle and reattach the junction box/receptacle to the
outer shell.
Heatilator • CNXT4236IT-C, CNXT4842IT-C, CNXT4236IH-C, CNXT4842IH-C • 2208-900 Rev. G • 10/10
Figure 12.2 Junction Box Detail
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
NOTICE: DO NOT wire
110 VAC to wall switch.