Reference Materials; Appliance Dimension Diagram - Heat & Glo ESCAPE-42DV Owner's Manual

Hearth and home technologies gas fireplace owner's installation and operation manual
Hide thumbs Also See for ESCAPE-42DV:
Table of Contents

Advertisement

16
16

Reference Materials

A. Appliance Dimension Diagram
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3.
G
H
I
ELECTRICAL
ACCESS
Figure 16.1 Appliance Dimensions
48
C
MINIMUM 24"
VERTICAL
REQUIRED
M
L
GAS LINE
ACCESS
N
K
J
Location
Inches Millimeters
A
48
1219
B
28-3/8
722
C
12
305
D
8
202
E
1/2
12
F
21
533
G
24
609
H
72-1/8
1831
I
2-5/8
66
J
4-1/4
107
Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08
A
B
Ø D
O
P
Location Inches Millimeters
K
11-5/8
296
L
3-5/8
91
M
1
24
N
41-3/8
1052
O
42
1068
P
56-7/8
1445
Q
37
939
R
52
1320
S
1-1/2
38
T
40-3/8
1062
F
E
R
Q
S
OPTIONAL FIRESCREEN
SITS OUT 1-1/2 INCHES
FROM UNIT FACE
T

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents