Clearances; Locating Fireplace - Empire Comfort Systems Studio DVP36DP31N-1 Owner's Manual

Studio series direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

Clearance to Combustibles
Back
Side
Floor
Top Stand-off
Top Framing Edge
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
FIRST 3 (SEE MAGNIFFIED
"
VIEW)
TOP FRAMING
LEDGE
GLASS FRONT
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Note: Empire "Standard Mantels" are not approved for use with
the DVP36DP(31,71,91)(N,P) Series fireplaces.
Note:** Island (C) and Room Divider
(D) installation is possible as long as the
horizontal portion of the vent system (H)
does not exceed 20 feet with a minimum
vertical run of 8 feet. See details in
Venting Section.
*When you install your Direct Vent
Fireplace in (D) Room divider or (E) Flat
on wall corner positions, a minimum of
6 inches clearance must be maintained
from the perpendicular wall and the front
edge of the appliance.
Page 8

CLEARANCES

0" (0 mm)
0" (0 mm)
0" (0 mm)
0" (0 mm)
3" (76 mm)
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
3"
NAILING
FLANGES
Figure 2

LOCATING FIREpLACE

CORNER
INSTALLATION
ANGLED CORNER
INSTALLATION
Mantel Chart (Figure 3)
Clearances (Figure 4)
Clearance from top of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
CABINET
INSTALLATION
ISLAND
INSTALLATION
Figure 5
Figure 3
36"
(914mm)
Figure 4
FLUSH WALL
INSTALLATION
ROOM DIVIDER
INSTALLATION
26408-0-1009