Venting Fireplace - Rear (Nat Models Only) - Empire Comfort Systems Studio DVP36DP31N-1 Owner's Manual

Studio series direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

vENTING FIREpLACE - REAR (NAT GAS MODELS ONLY)
To Use the vent Graph (Figure 38)
1. Determine the height of the center of the
horizontal vent pipe. Using this dimension on
the Sidewall Vent Graph, locate the point it
intersects with the slanted graph line.
2. From the point of this intersection, draw a vertical
line to the bottom of the graph.
3. Select the indicated dimension, and position the
unit in accordance with same.
EXAMpLE A:
If the vertical dimension from the floor of the unit
is 12 feet, 4 inches the horizontal run to the outer
wall flange must not exceed 12 feet, 3 inches.
EXAMpLE B:
If the vertical dimension from the floor of the unit is
6 feet, 9 inches, the horizontal run to the outer wall
flange must not exceed 6 feet, 6 inches.
SpECIAL NOTE: For each 45 degree elbow
installed in the horizontal run, the length of the
horizontal run MUST be reduced by 18" (45cm).
This does not apply if the 45 degree elbows are
installed on the vertical part of the vent system.
Reduce 3' for every 90° elbow.
Example: According to the chart the maximum
horizontal vent length is 20' and if two 45 degree
elbows are required in the horizontal vent it must
be reduced to 17'.
The maximum number of 45 degree elbows
permitted per side wall installation is two (2).
These elbows can be installed in either the vertical
or horizontal run.
Note: Only natural gas models can be rear
vented.
26408-0-1009
venting Graph (Dimensions in Feet)
REAR EXIT - VERTICAL AND HORIZONTAL TERMINATION
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
REAR HORIZONTAL
VENT CONNECTION
Acceptable vertical and horizontal vent run.
Unacceptable vertical and horizontal vent run.
(DIMENSIONS IN FEET)
A
B
HORIZONTAL RUN
Figure 38
Page 27