Empire Comfort Systems DVP36FP3 series Owner's Manual

Empire Comfort Systems DVP36FP3 series Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVP36FP3 series:
Table of Contents

Advertisement

EMPIRE
EMPIRE
Comfort Systems
Direct Vent Zero Clearance Gas
Fireplace Heater
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If the information in these instructions
are not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
GAS-FIRED
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
AND

DIRECT vENT

GAS FIREpLACE HEATER
MODEL SERIES
MILLIvOLT STANDING pILOT
Dvp36Fp3(0,1,2,3)(N,p)-5
DIRECT IGNITION
Dvp36Fp5(0,1,2,3)N-1
INTERMITTENT pILOT
Dvp36Fp7(0,1,2,3)(N,p)-5
REMOTE RF MODELS
Dvp36Fp9(1,3)(N,p)-5
UL FILE NO. MH30033
WARNING
DO NOT TOUCH
NEVER
HOT GLASS
WILL
CAUSE BURNS.
GLASS
UNTIL COOLED.
ALLOW CHILDREN
TO TOUCH GLASS.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems DVP36FP3 series

  • Page 1: Direct Vent

    INSTALLATION INSTRUCTIONS EMPIRE EMPIRE OWNER’S MANUAL Comfort Systems Direct Vent Zero Clearance Gas DIRECT vENT Fireplace Heater GAS FIREpLACE HEATER MODEL SERIES MILLIvOLT STANDING pILOT Dvp36Fp3(0,1,2,3)(N,p)-5 GAS-FIRED DIRECT IGNITION Dvp36Fp5(0,1,2,3)N-1 INTERMITTENT pILOT Dvp36Fp7(0,1,2,3)(N,p)-5 This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by state or local REMOTE RF MODELS...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Section page Important Safety Information ..............................3 Safety Information for Users of LP Gas ...........................4 Requirements for Massachusetts ............................5 Introduction ....................................6 Specifications ..................................7 Fireplace Dimensions ................................7 Clearances ....................................8 Locating Fireplace ...................................9 Gas Supply ....................................10 Rear Vent Conversion ................................11 Special Vent Systems ................................11 Installation ..................................
  • Page 3: Important Safety Information

    IMpORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED • If this appliance is installed directly on carpeting, • Adequate accessibility clearances for servicing and tile or other combustible material other than wood proper operation.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF Lp GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone’s safety colorless.
  • Page 5: Requirements For Massachusetts

    REqUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed SIGNAGE. A metal or plastic identification plate shall be in every dwelling, building or structure used in whole or in part for permanently mounted to the exterior of the building at a residential purposes, including those owned or operated by the minimum height of eight (8) feet above grade directly in line Commonwealth and where the side wall exhaust vent termination...
  • Page 6: Introduction

    National Fuel Gas Code ANSI Z223.1/NFPA • Modification of the fireplace or direct vent system. 54* Natural Gas and Propane Installation Code, or CSA B149.1 in • Installation other than as instructed by Empire Comfort Systems, Canada. *Available from the American National Standards Institute, Inc.
  • Page 7: Specifications

    SpECIFICATIONS Remote Control Description Dvp36 Nat Models Options & Input Btu/hr Maximum 25,000 Accessories Btu/hr Minimum (millivolt only) 18,000 FRBC Millivolt Battery Remote ON/OFF KWH (Maximum) FRBTC Millivolt Battery Remote T-Stat (Minimum) Millivolt Wireless Wall Thermostat Millivolt Reed Switch Wall Thermostat Orifice #41 (P256) FWS-1...
  • Page 8: Clearances

    CLEARANCES Mantel Chart (Figure 4) Clearance to Combustibles Back 0" (0 mm) 12” (305mm) Side 0" (0 mm) 10” (254mm) Floor 0" (0 mm) Top Stand-off 0" (0 mm) MANTEL Top Framing Edge 3" (76 mm) COMBUSTIBLE TRIM AND MANTELS 8”...
  • Page 9: Locating Fireplace

    LOCATING FIREpLACE Note:** Island (C) and Room Divider (D) installation is possible (E) Flat on wall corner positions, a minimum of 6 inches clearance as long as the horizontal portion of the vent system (H) does not must be maintained from the perpendicular wall and the front edge exceed 20 feet with a minimum vertical run of 8 feet.
  • Page 10: Gas Supply

    GAS SUppLY he gas pipeline can be brought in through the right or left Installing a New Main Gas Cock side of the appliance. Consult the current National Fuel Gas Each appliance should have its own manual gas cock. Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation A manual main gas cock should be located in the vicinity code.
  • Page 11: Rear Vent Conversion

    REAR VENT CONVERSION VERTICAL VENTING Lp and Nat models Note: Discard insulation HORIZONTAL VENTING & retainer when venting off Nat models only top of fireplace. INLET VENT Note : Discard insulation COVER PLATE & retainer when using vertical venting off Note : It is recommended that the FLUE COVER PLATE flue cover plate tab be pulled...
  • Page 12: Installation

    INSTALLATION Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. 3. Attach fireplace to frame using adjustable frame. Preset depth to suit facing material (adjustable to 1/2", 5/8"...
  • Page 13 INSTALLATION (continued) Note: For finishing to top of fireplace, refer to Figure 14. Flush Mount Mantel Installation (Figure 12) The fireplace must extend 3/4" beyond finished wall surface when using a flush mount mantel. Refer to Figure 12 to locate nailing flanges on fireplace sides.
  • Page 14 Flush Wall Installation Attention: Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall, it is recommended that the outer walls be insulated to conform to applicable insulation codes. vent Runs (Figures 16, 17, 18, 19 and 20) In planning the installation for the fireplace, it is necessary to install certain components before the appliance is completely positioned and installed.
  • Page 15: Installation

    INSTALLATION (continued) HoRIzonTAL onLY, STRAIGHT oUT THE BACK CORNER INSTALLATION vERTICAL, 90° ELBOW TO HORIzONTAL OUT THE WALL " A" PIPE LENGTH WALL FIRESTOP/ THIMBLE VENT VENT CAP WALL FIRESTOP/ THIMBLE Nat models only "A" "B" Lp and Nat models 6"...
  • Page 16: Venting Fireplace - Top (Lp And Nat Models)

    vENTING FIREpLACE - TOp (Lp & NAT MODELS) venting Graph (Dimensions in Feet) To Use the vent Graph (Figure 21) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line.
  • Page 17 vENTING FIREpLACE - TOp (continued) Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12" (305mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178mm) below grade level. The 7"...
  • Page 18 10” (254mm) 10” (254mm) minimum Lp and Nat models Figure 26 Lp and Nat models Figure 25 MAXIMUM HORIZONTAL RUN WITH NO VERTICAL MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH RISE AND 90° ELBOW THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE FIREpLACE HARD ELBOW DIMENSIONS...
  • Page 19: Dvvk-4Fv Direct Vent Termination Kit

    DVVK-4FV DIRECT VEnT TERMInATIon KIT Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the fireplace model number.
  • Page 20 pRE-INSTALLATION INFORMATION: Items Required For Installation: Tools Building Supplies Phillips Screwdriver Framing Materials Hammer Wall Finishing Materials Saw and/or saber saw Caulking Material (Noncombustible) Level Support Strap supplies Measuring Tape Electric Drill and Bits Pliers Square Tin Snips Before You Start: Plan your installation.
  • Page 21 DVVK-4FV DIRECT VEnT TERMInATIon KIT (continued) Step-By-Step Installation For Flex DV Kit Unpack vent components and check all items for shipping Next, determine the location for the cutout in the roof opening. damage. This opening must be large enough to provide a minimum 1” For this venting system to operate as designed it is dependent air space clearance from the vertical vent pipe to any combus- on the use of all parts and procedures detailed in these in-...
  • Page 22 DVVK-4FV DIRECT VEnT TERMInATIon KIT (continued) 10. With the flex vent assembly and the 48” long hard pipe com- 13. Now the pre-assembled vent system may be carried to the ponents laid out on the floor, begin securing these parts to- roof, then lowered through the roof cutout opening (see step gether.
  • Page 23 DVVK-4FV DIRECT VEnT TERMInATIon KIT (continued) 17. To attach the vent connections at the fireplace, be sure the 7” 21. An additional storm collar band is provided in kit that may be diameter adapter collar has been installed per step 3. Apply a used as an attic insulation shield.
  • Page 24 DVVK-4FV DIRECT VEnT TERMInATIon KIT (continued) Vertical Termination Storm 4' Long Rigid Pipe Collar Roof Flashing Adjustable Roof Jack Roof Assembly Exterior Clearance to Combustibles Required From Vent Pipe Clamps At Flue & Inlet Vent Connections Adjustable Storm Collar (Use TO Firestop/Thimble Keep Insulation Out Of Assembly...
  • Page 25: Dvvk-4Fv Direct Vent Termination Kit

    DVVK-4FV DIRECT VEnT TERMInATIon KIT (continued) Vertical Flex Termination Kit Item quantity Number Item Description Repair part No. Supplied 4”/7” Vertical Termination Cap MF100038 Roof Support Kit MF100503 2 Ply Alum Flex 4” Diameter by 6 ft. MF04ALA2F006 2 Ply Alum Flex 7” Diameter by 6 ft. MF07ALA2F006 4”/7”...
  • Page 26: Examples - Top Vent Run

    EXAMpLES - TOp vENT RUN 24” 24” MINIMUM CLEARANCE TO COMBUSTIBLES Lp and Nat models Figure 36 Lp and Nat models Figure 35 Lp and Nat models Figure 37 Page 26 26930-5-1010...
  • Page 27: Venting Fireplace - Rear (Nat Models Only)

    vENTING FIREpLACE - REAR (NAT GAS MODELS ONLY) venting Graph (Dimensions in Feet) To Use the vent Graph (Figure 38) 1. Determine the height of the center of the REAR EXIT - VERTICAL AND HORIZONTAL TERMINATION horizontal vent pipe. Using this dimension on the (DIMENSIONS IN FEET) Sidewall Vent Graph, locate the point it intersects with the slanted graph line.
  • Page 28: Examples - Rear Vent Run

    EXAMpLES - REAR vENT RUN Model Maximum Pipe Length H1 DVP36 24" Nat models only Figure 41 Nat models only Figure 39 Model Maximum Pipe Length H1 DVP36 24" Nat models only Nat models only Figure 42 Figure 40 Page 28 26930-5-1010...
  • Page 29: Termination Clearances

    TERMINATION CLEARANCES Termination clearance for buildings with combustible and noncombustible exteriors. Figure 43 vertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is three (3") (76mm) on top, and (1") (25mm) on bottom and sides. Important! When vent termination exits through foundation less than 20" below siding outcrop, the vent pipe must extend outward so that the horizontal vent terminal is located flush to, or beyond the outcrop siding.
  • Page 30: Vent Clearances

    vENT CLEARANCES Figure 44 *Clearance above grade, veranda, porch, deck or balcony clearance to non-mechanical air supply inlet to building or [*12 inches (30cm) minimum] the combustion air inlet to any other appliance [*12 inches (30cm) minimum for appliances ≤ 100,000 Btuh (30 kW) clearance to window or door that may be opened [*12 inches (30cm) minimum for appliances <...
  • Page 31: Vent System Identification

    (MAXIMUM OF THREE 90 ELBOWS) (MAXIMUM OF TWO 90 ELBOWS) Special venting components (Simpson Duravent) See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers and pricing. Special DV Vent Kits Available from Empire Comfort Systems, Inc. dealers. DVVK-4VP...
  • Page 32: Framing And Finishing

    FRAMING AND FINISHING Installing Support Brackets (Figure 46) A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to combustibles above 6 5/8 inch diameter pipe and elbows and 1 inch clearance on both sides and bottom of 6 5/8 inch pipe to 10”...
  • Page 33 FRAMING AND FINISHING (continued) Figure 48 Figure 50 See Horizontal Termination Page 34 and vertical Termination Pages 39-40. Figure 49 26930-5-1010 Page 33...
  • Page 34: Horizontal Termination

    HORIzONTAL TERMINATION NOTE: Termination cap should pass through the wall firestop from SNORKEL the exterior of the building. Adjust the termination cap to its final exterior position on the building. WARNING: Termination cap must be positioned so that arrow is pointing up. Attach the termination cap with the four wood screws provided.
  • Page 35: Dvvk-4Re Vent Kit Installation Instructions

    DVVK-4RE VEnT KIT InSTALLATIon InSTRUCTIonS CAUTION: Sharp edges, use protective gloves when NOTE: SPACING FLANGE installing. INSTALLED TO TOPSIDE Tools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature sealant or furnace cement rated for continuous use at 1,000 F minimum Measuring tape...
  • Page 36 DVVK-4RE VEnT KIT InSTALLATIon InSTRUCTIonS (continued) 8. Attach the 4” (102mm) diameter flue outlet tube onto the rigid venting system or directly to fireplace. Ensure the 4” (102mm) VINYL SIDING KIT DV822 diameter flue outlet tube is placed as far as possible onto the rigid venting system.
  • Page 37: Dvvk-4Re Vent Kit Installation Instructions

    DVVK-4RE VEnT KIT InSTALLATIon InSTRUCTIonS (continued) Follow correct option according to venting method. Connecting to Rigid vent System If the air inlet and flue outlet tubes are to be connected to a rigid Connecting Directly to Fireplace venting system (and not directly to the back of the unit), then do If the air inlet and flue outlet tubes are to be connected directly to not use the gasket provided.
  • Page 38: Dvvk-4F Flex Vent Instructions

    DVVK-4F FLEX VEnT InSTRUCTIonS The DVVK-4F FLEX VEnT KIT includes the following components: • (1) Horizontal Termination Cap • (1) 7" diameter outer vent adapter collar • (1) 4-foot section of Flex vent with spacers (4" flue/7" outer • (1) Wall Firestop/Thimble Assembly pipe) •...
  • Page 39: Vertical Termination

    vERTICAL TERMINATION Locate and mark the center point of the venting pipe. Using a nail When terminating the vent cap near an exterior wall or overhang, on the underside of the roof and drive this nail through this center maintain minimum clearances as shown in Figure 60. point.
  • Page 40: Vertical Termination

    If damage occurs to the combustion chamber, it must be replaced by a qualified service person. Contact Empire Comfort Systems, Inc. for replacement parts. vertical Through the Roof Applications (Figure 62) Your Gas Fireplace has been approved for: a) Vertical installations up to 40 feet in height.
  • Page 41: Log Placement - 4 Log Set

    LoG PLACEMEnT (4 LoG SET) Before you begin: This fireplace is supplied with a set of three ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fiber.
  • Page 42: Operating Instructions

    OpERATING INSTRUCTIONS 750 Millivolt System Initial Lighting The standing pilot (750 millivolt system) is a continuous burning pilot. Upon completing the gas line or turning the gas valve on after it has The pilot remains ON even when the main burner is OFF. been in the “OFF”...
  • Page 43: Operating Instructions

    OpERATING INSTRUCTIONS (continued) STANDING pILOT OpERATING INSTRUCTIONS Installation of Remote Receiver REMOTE/OFF/ON Switch Place remote receiver on the floor of fireplace behind the louver as The fireplace is equipped with a REMOTE/OFF/ON switch. A far forward as possible. wire harness is attached to the REMOTE/OFF/ON switch. The Attention: The Velcro loop and hook are not necessary in this red, black and green (wires) female push-ons attach to the installation but can be used to secure remote receiver.
  • Page 44: Standing Pilot Wiring Diagram

    STANDING pILOT WIRING DIAGRAM (OPTIONAL) THERMOSTAT (OPTIONAL) WALL SWITCH Figure 68 Page 44 26930-5-1010...
  • Page 45: Standing Pilot Lighting Instructions

    STANDING pILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When ment.
  • Page 46: Standing Pilot Troubleshooting

    STANDING pILOT TROUBLESHOOTING With proper installation and maintenance, your new Direct vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
  • Page 47: Direct Ignition Wiring Diagram

    DIRECT IGNITION WIRING DIAGRAM GAS VALVE SPARK IGNITOR VALVE DE GAZ (OPTIONAL) WALL SWITCH OR THERMOSTAT ÉTINCELLE ALLUMER INTERRUPTEUR MURAL (FACULTATIVE) CONTROL MODULE (OPTIONAL) REMOTE CONTROL AUTORITÉ MODULE RECEIVER 120V (FACULATIVE) CONTROLE E DISTANCE DU RECEPTEUR 120 VAC LINE BLACK NOIR 120 VAC RTN BLACK NOIR WHITE BLANC...
  • Page 48: Direct Ignition Lighting Instructions

    DIRECT IGNITION LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXpLOSION MAY RESULT CAUSING pROpERTY DAMAGE, pERSONAL INJURY, OR LOSS OF LIFE. A. BEFORE LIGHTING smell all around the appliance area B.
  • Page 49: Initial Start Up Gas Line Purge

    INITIAL START UP GAS LINE PURGE NOTE: UNIT MUST BE pROpERLY GROUNDED FOR ELECTRONIC IGNITION TO FUNCTION. On initial installation, or after extended periods where the fireplace has not been used, gas lines may require purging. The installer or qualified service person may use the following purge procedures to prevent the delays that would be caused by waiting for the lockout periods between tries for ignition.
  • Page 50: Direct Ignition Propane/Lp Gas Conversion

    DIRECT IGNITION PROPANE/LP GAS CONVERSION The conversion shall be carried out in accordance with the 12. Install propane/LP main burner orifice marked 1.55 mm. requirements of the provincial authorities having jurisdiction Important: Failure to install the correct orifice will result in and in accordance with the requirements of the CSA B149.2 unit over-firing that could overheat the appliance and result installation code (Canada) and with the requirements of the...
  • Page 51 DIRECT IGNITION PROPANE/LP GAS CONVERSION Maxitrol valve Conversion REGULATOR FITTING NOTE: STAMPED WITH GAS TYPE SET FOR USE Model AIR SHUTTER BURNER ORIFICE Figure 71 SETTINGS Opening "A" Propane/LP Orifice DVP36 FULL OPEN 1.55 mm Figure 70 26930-5-1010 Page 51...
  • Page 52: Intermittent Pilot Operating Instructions

    INTERMITTENT pILOT OpERATING INSTRUCTIONS The intermittent pilot (120/24 volt system) is ON when the main Provided on the intermittent pilot wiring harness are two (2) stripped burner is ON. When the main burner is OFF the intermittent pilot and bare wires that are labeled THERMOSTAT. The wires will be is OFF.
  • Page 53: Intermittent Pilot Lighting Instructions

    INTERMITTENT pILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition •...
  • Page 54: Intermittent Pilot Troubleshooting

    Type of gas being used and that shown on the rating label. STEP 4: Check Safety Lockout Operation. The Service Department at Empire Comfort Systems, Inc. may be A. Turn gas supply off. contacted to assist in servicing furnace.
  • Page 55 INTERMITTENT pILOT TROUBLESHOOTING the spark generator and energizes the second main valve operator. Safety Lockout The second main valve opens and gas flows to the main burner, S8600H provides 100 percent shutoff, or safety lockout. A timer where it is ignited by the pilot burner. The flame current also holds starts timing the moment the trial for ignition starts.
  • Page 56 INTERMITTENT pILOT TROUBLESHOOTING (continued) Important WARNING 1. The following service procedures are provided as a general When performing the following steps, do not touch stripped guide. end of jumper or SPARK terminal. The ignition circuit 2. Meter readings between gas control and ignition module must generates 13,000 volts at 25 pf load and electrical shock be taken within the trial for ignition period.
  • Page 57 INTERMITTENT pILOT TROUBLESHOOTING (continued) 26930-5-1010 Page 57...
  • Page 58: Intermittent Pilot Troubleshooting

    INTERMITTENT pILOT TROUBLESHOOTING (continued) Green LED Status Codes Green LED Flash Code (X + Y) Indicates Next System Action Recommended Service Action No “Call for Heat” Not applicable None Flash Fast Startup-Flame sense calibration Not applicable None Heart Beat Normal operation Not applicable None Recycle...
  • Page 59: Rf Operating Instructions

    RF OpERATING INSTRUCTIONS RF VALVE oPERATIon (AF-4040 Electronic Gas Valve system When the remote/off switch is in the OFF position the appli- only) ance will operate from an appliance mounted rocker switch Please refer to the separate instructions for detailed operation and (#3) or optional wall switch connected to the two (2) BROWN programming of the Multi-function Remote Control.
  • Page 60: Rf Maintenance

    RF MAINTENANCE INSTRUCTIONS MAINTENANCE TROUBLESHOOTING Maintenance frequency must be determined individually for each IMPORTANT: All service and trouble-shooting procedures should application. Some considerations are: be performed by an experienced qualified service technician. • Exposure to water, dirt, chemicals and heat can damage the If the pilot will not stay lit: gas control and shut down the control system.
  • Page 61: Rf Wiring Diagram

    RF WIRING DIAGRAM BLOWER BATTERY BACK-UP 120V EXTENSION LIGHT TRANSFORMER MODULE (OPTIONAL) ON/OFF BROWN SWITCH WHITE GREEN GAS CONTROL ORANGE VALVE POWER Stepper PILOT Motor MAIN (GND) PILOT ELECTRONIC WHITE CONTROL MODULE ORANGE JUNCTION BOX Note: For "RF" Fireplace models with Premium Multi-Function Remote Control, Refer to the separate instructions for operation of the remote control system.
  • Page 62: Rf Lighting Instructions

    RF STANDING pILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXpLOSION MAY RESULT CAUSING pROpERTY DAMAGE, pERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by knob.
  • Page 63: Maintenance And Service

    MAINTENANCE AND SERvICE WARNING: Do not use abrasive cleaners on glass. Do not pLEASE NOTE attempt to clean glass when glass is hot. It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start Glass Removal and Replacement (Figure 74) up or cool down cycle.
  • Page 64: Parts View

    pARTS vIEW MILLIVOLT BURNER ASSEMBLY RF VALVE BURNER ASSEMBLY INTERMITTENT PILOT BURNER ASSEMBLY BLOWER ASSEMBLY - RF MODELS LOG SET ASSEMBLY DI BURNER ASSEMBLY Page 64 26930-5-1010...
  • Page 65: Parts List

    pARTS LIST Index No. part Number Description Dvp36Fp3 Dvp36Fp5 Dvp36Fp7 Dvp36Fp9 R7654 R7654 R7654 R7654 Insulation, Flue 17426 17426 17426 17426 Retainer, 5” Flue R7566 R7566 R7566 R7566 Vent Adapter R7573 R7573 R7573 R7573 Vent Gasket 17155 17155 17155 17155 Flue Outlet Assembly M163 M163...
  • Page 66: Parts List

    pARTS LIST (continued) Index No. part Number Description Dvp36Fp3 Dvp36Fp5 Dvp36Fp7 Dvp36Fp9 16223 16223 16223 16223 Spring Retainer Assembly R3435 R8147 R721 Wire Assembly R2708 Piezo Ignitor R3436 Remote/On/Off Switch R1995 Transformer (IP) R7615 R5160 Cord Set R8144 Wire Harness (DI) R5751 Wire Harness (IP) 18880...
  • Page 67: Fbb4 Optional Variable Speed Blower Installation

    FBB4 oPTIonAL VARIABLE SPEED BLoWER InSTALLATIon Attention: Install blower assembly before connecting gas 5. Insert blower assembly into interior, bottom of fireplace. inlet supply line Position blower assembly behind gas valve, align notch on back of blower assembly with center screw Note: junction box on right side of fireplace must be pre- on fireplace back and push blower assembly against wired at time of fireplace installation for use with...
  • Page 68 FBB4 oPTIonAL VARIABLE SPEED BLoWER InSTALLATIon FBB4 B L O W E R A S S E M B L Y COMpLETE R7649 FAN CONTROL R4192 SPEED ConTRoL KnoB R4186 SpEED CONTROL 110 VOLT AC JUNCTION BOX BLACK SWITCH WHITE GROUND SPEED CONTROL...
  • Page 69: Junction Box Wiring Installation Instructions

    JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS CAUTION: ALL WIRING SHOULD BE DONE BY A qUALIFIED ELECTRICIAN AND SHALL BE IN COMpLIANCE WITH ALL LOCAL, CITY AnD STATE BUILDInG CoDES. BEFoRE MAKInG THE ELECTRICAL ConnECTIon, MAKE SURE THAT MAIn PoWER SUP- pLY IS DISCONNECTED. THE AppLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFpA 70 (LATEST EDITION).
  • Page 70: Accessories

    ACCESSORIES The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623. Accessory Description Model Number Fan Kit This fan kit was designed to provide forced air flow.
  • Page 71: Master Parts Distributors List

    For the current list, please click on the Master Parts button at www.empirecomfort.com. Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. Star-Fire Distributors...
  • Page 72: Quick Reference Guide

    Empire Comfort Systems Web Site www.empirecomfort.com EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems The Tahoe Direct Vent Zero Clearance Gas Fireplace Heater GAS-FIRED MILLIvOLT STANDING pILOT: Dvp36Fp3(0,1,2,3)-5 (NAT, Lp) INTERMITTENT pILOT: Dvp36Fp7(0,1,2,3)-5 (NAT, Lp) REMOTE RF MODELS: Dvp36Fp9(1,3)-5 (NAT, Lp)
  • Page 73: Firebox Dimensions

    Empire Comfort Systems Web Site www.empirecomfort.com EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems The Tahoe Direct Vent Zero Clearance Gas Fireplace Heater GAS-FIRED MILLIvOLT STANDING pILOT: Dvp36Fp3(0,1,2,3)-5 (NAT, Lp) INTERMITTENT pILOT: Dvp36Fp7(0,1,2,3)-5 (NAT, Lp) REMOTE RF MODELS: Dvp36Fp9(1,3)-5 (NAT, Lp)
  • Page 74: Appliance Service History

    AppLIANCE SERvICE HISTORY Date Dealer Name Service Technician Name Service performed/Notes Page 74 26930-5-1010...
  • Page 75: Appliance Service History

    AppLIANCE SERvICE HISTORY Date Dealer Name Service Technician Name Service performed/Notes 26930-5-1010 Page 75...
  • Page 76 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com...