Vent Clearances - Empire Comfort Systems Studio DVP36DP31N-1 Owner's Manual

Studio series direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

A =
*Clearance above grade, veranda, porch, deck or balcony
[*12 inches (30cm) minimum]
B =
clearance to window or door that may be opened [*12 inches
(30cm) minimum for appliances < 100,000 Btuh (30kW)
C =
clearance to permanently closed window [minimum 12
inches (30cm) recommended to prevent condensation on
window]
D =
vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of 24 inches (60 cm) from
the center of the terminal [18 Inches (46 cm) minimum
E =
clearance to unventilated soffit [12 inches 30cm)
minimum]
F =
clearance to outside corner. See page 33.
G =
clearance to inside corner. See page 33.
H =
*not to be installed above a meter/regulator assembly
within 3 feet (90cm) horizontally from the center-line of
the regulator
I =
clearance to service regulator vent outlet [*6 feet (1.8m)
minimum]
Page 34

vENT CLEARANCES

Figure 49
J =
K =
L =
M =
¥
*
clearance to non-mechanical air supply inlet to building or
the combustion air inlet to any other appliance [*12 inches
(30cm) minimum for appliances ≤ 100,000 Btuh (30 kW)
36 inches (90cm) minimum for appliances > 100,000 Btuh
(30kW)]
clearance to a mechanical air supply inlet [* 6 feet (1.8m)
minimum]
†clearance above paved sidewalk or a paved driveway located
on public property [*7 feet (2.1m) minimum]
clearance under veranda, porch, deck, or balcony [*12 inches
(30cm) minimum ¥]
a vent shall not terminate directly above a sidewalk or
paved driveway which is located between two single family
dwellings and serves both dwellings*
Only permitted if veranda, porch, deck, or balcony, is fully
open on a minimum of 2 sides beneath the floor*
As specified in CGA B149 Installations Codes or ANSI
Z223.1. Note: Local Codes or Regulations may require
different clearances.