RF VALVE oPERATIon (AF-4040 Electronic Gas Valve sys-
tem only)
Please refer to the separate instructions for detailed operation and
programming of the Multi-function Remote Control.
The AF-4040 Electronic Gas Control Valve features a Remote
controlled High/Low Variable - 6 Volt DC Motor Drive. This gas
control uses a spark to pilot burner assembly. For use with Pro-
pane or natural gas (pre-set at the factory).
This gas control system includes the items identified in Figure
73.
SpECIAL FEATURES ON THE CONTROL MODULE
The Control Module has two special pilot mode features built into
the system.
CONTINUOUS pILOT FEATURE: This allows the user to
change from a spark to pilot system to a standing pilot system.
1. There is a switch located on the right side of the Control
Module (#4) that reads CONTINUOUS PILOT ON/OFF.
This switch will allow the user to select the pilot mode of
operation.
2. When the continuous pilot switch is in the OFF position and
the appliance turned ON, the pilot will spark and light, then
the main burner will light as well. When the appliance is
turned OFF, the pilot and main burner will shut OFF.
3. When the continuous pilot switch is in the ON position and
the appliance is turned ON, the pilot will spark and light.
Then when the appliance is turned OFF the pilot will remain
ON, but the main burner will shut OFF.
Note: The Continuous pilot mode setting is generally recom-
mended on Direct Vent appliances during cold climate sea-
sons to help keep the firebox warm.
REMOTE CONTROL FEATURE: The Control Module has a
built in remote control receiver which allows the user to program
the hand held remote transmitter.
1.
There is a switch located on the right side of the Control
Module that reads REMOTE/OFF.
26408-0-1009

RF OpERATING INSTRUCTIONS

2
1
Index No.
part No.
1
R10418
2
R10415
3
R2522
4
R10417
5
R10416
6
R10419
R10423
7
R10424
2. When the remote/off switch is in the OFF position the appli-
ance will operate from an appliance mounted rocker switch
(#3) or optional wall switch connected to the two (2) BROWN
wires on the Control Module.
3. When the remote/off switch is in the REMOTE position the
appliance will operate from the Remote Control transmitter.
The Control Module must be programmed to the Remote Con-
trol.
1. To program, located the learn button on the left side of the
Control Module Note: Press and release the learn button.
There will be a beep sound from the Control Module, then
press any key on the remote transmitter. Once the internal
receiver accepts the transmitter code there will be a series of
confirming beeps.
2. The remote system is ready for use. Please refer to the sepa-
rate Mult-function Remote Control Instruction manual for
programming and detailed operational information.
pOWER SUppLY SYSTEM
The Gas Control system is powered by a standard 110 volt AC
through a 6.0 volt DC adaptor. The AC adaptor is connected to the
Control Module with two 1/4" female terminals.
This control system also includes a Battery Back-up pack that al-
lows the Gas Control system only to operate in the event of a
power outage.
NOTE: The Accent Light and/or Blower features will not operate
during a power outage.
NOTE: All Batteries should be replaced at least once each year,
preferably at the beginning of the heating season.
CAUTION: Fire or explosion hazard. Can cause property dam-
age, sever injury or death.
Do not attempt to take apart the gas control or to clean it. Improp-
er assembly and cleaning can cause unreliable operation.
7
3
4
Description
Battery Back-up
AF Valve, RF
Off/On Switch
AF Control Module
AF Extension Module
AC Adapter
Pilot Assembly - Nat
Pilot Assembly - LP
Figure 73
6
5
Page 59