When inputting BETACAM with YC
When receiving 480i with analog component signal YCbCr input, it is possible to switch Cb, Cr input.
Switching procedure
• This function can be used only when input is done with an analog RGB input module (ET-MD95RGB).
NOTE
• This function enables switching only when receiving 480i in YCbCr mode. Switching cannot be done in
RGB REALITY mode, RGB mode, or when receiving signals other than 480i.
• The initial value is SMPTE.
Method of switching input impedance(signal level)for sync input
With analog RGB input, it is possible to switch the input impedance (signal level) of the sync signal. When
connecting with equipment (like a signal selector) whose sync output impedance is 75 ohm, use 75 ohm, and when
connection with equipment (like a PC video card) whose sync output is TTL, switch to TTL (HI-Z).
Switching procedure
NOTE
• This function can be used only when input is done with an analogue RGB input module (ET-MD95RGB).
• Use by switching for each input signal.
• The initial value is 75 ohm.
• When this switching is performed, the CLOCK phase and image position may shift, so adjust again.
64
Press the MENU button. ... The MENU screen will be displayed.
Press the UP (
) and DOWN (
Press the ENTER button. ... The PICTURE screen will be displayed.
Press the UP (
) and DOWN (
Press the LEFT (
) and RIGHT (
• Switching is done with the SMPTE and BETACAM toggle.
Signal level
System
SMPTE
BETACAM
Press the MENU button. ... The MENU screen will be displayed.
Press the UP (
) and DOWN (
Press the ENTER button. ... The OPTION screen will be displayed.
Press the UP (
) and DOWN (
Press the LEFT (
) and RIGHT (
(signal level) of sync signal.
• Switching is done using the 75 ohm and TTL (HI-Z) toggle.
SYNC TERM.
75 ohm
Amplitude:0.6 V [p-p] 4.0 V [p-p]
High level : more than 2.0 V
TTL(HI-Z)
Loe level : Less than 0.8 V
Cr 480i
b
) arrow buttons to select PICTURE.
) arrow buttons to select FORMAT.
) arrow buttons to switch signal format.
Sync part
Y
700 mV
300 mV
286 mV
714 mV
) arrow buttons to select OPTION.
) arrow buttons to select SYNC TERM.
) arrow buttons to switch input impedance
Input Impedance
Signal Level
C
Cr
b,
350 mV
504 mV
75
1 k