Quadra-Fire HUDBAY-FS Owner's Manual
Quadra-Fire HUDBAY-FS Owner's Manual

Quadra-Fire HUDBAY-FS Owner's Manual

Hudson bay direct vent gas appliance
Hide thumbs Also See for HUDBAY-FS:
Table of Contents

Advertisement

• Important operating and
maintenance instructions
included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance.
Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians supervised by an NFI
certified professional.
Page 1
HUDSON BAY
DIRECT VENT GAS APPLIANCE
Owner's Manual

Installation and Operation

Model:
HUDBAY-FS
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and
follow these instructions
for safe installation and
operation.
Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber or gas
fitter.
See Table of Contents for additional Commonwealth of Mas-
sachusetts requirements.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
R
O-T L
Tested and
Portland
Oregon USA
Listed by
C
US
OMNI-Test Laboratories, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire HUDBAY-FS

  • Page 1: Installation And Operation

    Technologies suggests NFI certified or factory-trained CAN/CSA Z240MH. professionals, or technicians supervised by an NFI This appliance is only for use with the type(s) of gas indicated certified professional. on the rating plate. Page 1 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 2 Fourniture Électrique: 120 Volts, 1.2 Amps, 60 Hz Efficacité Thermique Jusqu'à: 84.02% NG (avec ventilateur allumé) 85.71% LP (avec ventilateur allumé) P.4.1-02 Le canada tuyau minimum: 64.03% NG / 65.43% LP 7003-950 7003-951 Serial Number Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 2...
  • Page 3: Table Of Contents

    E. Warranty ..........47 Section 6: Gas Information  F. Contact Information ......49 A. Fuel Conversions ........22 B. Gas Pressures ........24 C. Gas Connection........25  = Contains updated information. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 3...
  • Page 4: Section 1: Listing And Code Approvals

    Page 4 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.” See Gas Connection section for additional Common- wealth of Massachusetts requirements. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 5...
  • Page 6: Section 2: Getting Started

    Flat Blade Screwdriver Voltmeter Plumb Line Gloves Level Safety Glasses Manometer Non-corrosive Leak Check Solution or combustible gas detector Tape Measure Caulking material (300ºF minimum continuous exposure rating) Page 6 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 7: Selecting Appliance Location

    Check with flooring • USE wood flooring, ceramic tile, brick hearth manufacturer for maximum temperature allowed on flooring or high pressure laminate flooring applied surfaces. directly over the sub-flooring material. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 7...
  • Page 8: Section 4: Termination Locations

    In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap. Figure 4.2 Multiple Vertical Termination Page 8 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 9 CAUTION: IF EXTERIOR WALLS ARE FINISHED to the electrical service. WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED (part #VPK- DV). Figure 4.4 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 9...
  • Page 10: Section 5: Vent Information

    Vertical terminations are measured to the top of the last May impair safe operation of this appliance or pipe before termination cap. other appliances connected to the flue. • Horizontal pipe installed level with 1/4 in. rise. Page 10 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 11: How To Use The Vent Graph

    VERTICAL DISTANCE FROM APPLIANCE TO TO THE 90° ELBOW EX. 1 11" 2' 14' 15' (MAX) (MIN) TOTAL HORIZONTAL RUN TO OUTSIDE OF ExTERIOR WALL (INCLUDING ELBOWS) Figure 5.2 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 11...
  • Page 12: Horizontal Termination

    The female locking lugs may not be visible from the outside, on the pipe or fittings. They may be located by examining the inside of the female ends. Page 12 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 13 The vent termination cap shall not be recessed into a wall or siding. Remove siding from the area where the standoff will be located. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 13...
  • Page 14 Note: The attachment from the vent pipe to the vent termination cap must be sealed with silicone. Termination caps shall not be recessed into a wall or siding. Page 14 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 15: Vertical Termination

    • Do not pack air space with insulation or other Figure 5.12 materials. Failure to keep insulation or other materials away from vent pipe may cause fire. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 15...
  • Page 16 Figure 5.14. Verify that the chimney is the required height above the roof. See roof pitch table, Figure 4.3 on page 8. Page 16 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 17 Do not fill any of the required air space with insulation. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 17...
  • Page 18 Ensure that all pipe and elbow connections are in their CATHEDRAL fully twist-locked position. Assemble as instructed. CEILING SUPPORT SCREWS Figure 5.19 Page 18 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 19 Sheet Metal Screws Step 7. The connection between the appliance and the retro connector may be completed with sections of direct vent Figure 5.21 pipe. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 19...
  • Page 20 (Figure 5.25). line up the flex liner with the vent opening on the appliance. Page 20 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 21 FOUR MASONRY BOLTS (NOT INCLUDED) Figure 5.30 Step 11. The connection between the appliance and the retro connector may be completed with sections of direct vent FLASHING Figure 5.28 pipe. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 21...
  • Page 22: Section 6: Gas Information

    Burner support screws locations Slide the burner support to the left to access the Figure 6.4 orifice. Page 22 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 23 Ensure that the rubber gasket (D) is properly posi- Figure 6.9 tioned and install the new HI/LO pressure regulator assem- bly to the valve using the new screws (E) supplied with the Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 23...
  • Page 24: Gas Pressures

    Contact the local gas supplier if the regulator is at an improper pressure. Page 24 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 25: Gas Connection

    • Gas build-up during line purge may ignite. • Purge should be performed by qualified technician. • Ensure adequate ventilation. • Ensure there are no ignition sources such as sparks or open flame. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 25...
  • Page 26: Section 7: Electrical Information

    18 feet Keep wire lengths as short as possible by removing any excess wire length. Low voltage and 110 VAC voltage cannot be shared within the same wall box. Page 26 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 27 • Replace damaged wire with type 105 Wiring errors can cause improper and dangerous operation. rated wire. Verify proper operation after servicing. • Wire must have high temperature insulation. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 27...
  • Page 28: Section 8: Appliance Setup

    Holding the ashlip, lift the door up off of the stationary latches all fingerprint oils from the gold or nickel surface of crown and away from the appliance. PRIOR to lighting the appliance. Page 28 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 29: Grille Installation

    Figure 8.6 remove the brick refractory. Removal of the bracket requires removing two screws. Still holding the baffle in place, install the left brick Figure 8.9 into position. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 29...
  • Page 30: Positioning The Logs

    8.6. The pilot shield must be in place before operation of appliance. Install the left rear log (#3) over the locater pins Figure 8.15 in the burner pan. Page 30 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 31: Mineral Wool

    NOTE: Do not block gas ports. Install the left twig (#6) over the locater pins in the Figure 8.18 right rear log and the left front log. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 31...
  • Page 32: Blower Installation

    Fan Speed Control F = Female spade connector M = Male spade connector Power Cord (110 VAC) Ground Strain Relief Bushing Fan Assembly Figure 8.23 Blower Wiring Diagram Page 32 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 33: Damper Adjustment

    Moving the shutter bolt to the right closes the shutter. Moving the shutter bolt to the left, will open the shutter. Opening the shutter causes flames to become shorter and blue. Closing the shutter creates taller orange/yellow flames. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 33...
  • Page 34: Section 9: Operating Instructions

    • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. • Keep clothing, furniture, draperies and other flammable materials away. Page 34 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 35: Lighting Appliance

    2. Turn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 35...
  • Page 36: After Appliance Is Lit

    Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the appliance. Page 36 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 37: Section 10: Troubleshooting

    With the pilot in the ON position, disconnect the thermopile leads from the valve. Take a reading at the thermopile leads. The reading should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 37...
  • Page 38 Ensure that the glass is tightened properly on the appliance, particu- larly on top corners. Page 38 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 39 • Odors WARNING Inspect external vent cap regularly. • Ensure no debris blocks cap. • Combustible materials blocking cap may ignite. • Restricted air flow affects burner operation. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 39...
  • Page 40: Maintenance Tasks

    4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and flashing remains intact. Remote Controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Page 40 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 41: Section 12: Reference Materials

    A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For clearances refer to Section 3. Location Inches Millimeter 22-3/8 9-3/4 28-1/2 Figure 12.1 Appliance Dimensions Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 41...
  • Page 42: Vent Components Diagram

    167 mm 167 mm 167 mm 167 mm SLP48 SLP12 SLP36 SLP24 Note: Pipes overlap 1-3/8 inches (34.93 mm) at each joint. Figure 12.2 SLP Series Vent Components Page 42 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 43: Vent Components List

    Storm Collar SLP-FS Ceiling Firestop SLP-WS Wall Firestop SLP-HVS Pipe Support Hanger Vinyl Protector Kit - SL Pipe DRC-RADIUS Decorative Radius Cover HTI-DV-WT Wall Thimble RF4-8 Roof Flashing Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 43...
  • Page 44: Service Parts List

    D. Service Parts HUDBAY-FS Service Parts Hudson Bay Free Standing Beginning Manufacturing Date: April 2003 Ending Manufacturing Date: Active Log Set Assembly Part number list on following page. 08/13 Page 44 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 45 11.4 Air Shutter Assembly 468-5060 11.5 Bulkhead 26457 11.6 Bulkhead Stop 474-0090 11.7 Pilot Assembly 842-4940 11.8 Pilot Shield PS-7008 Additional service part numbers appear on following page. Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 45...
  • Page 46 Touch Up Paint TUP-GBK-12 Post SN 0021621084 Conversion Kit NG Conversion Kit LP LPK-7008 Pilot Orifi ce NG 842-4440 Pilot Orifi ce LP 200-2630 Regulator NG 230-1570 Regulator LP 230-1520 Page 46 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 47: Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13 Page 47...
  • Page 48 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Page 48 Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13...
  • Page 49: Contact Information

    Quadra-Fire, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044 www.quadrafire.com Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, please visit our web site www.quadrafire.com CAUTION Do NOT discard this manual.

This manual is also suitable for:

Hudson bay

Table of Contents