kit. Tighten screws securely. (Reference torque = 25 in./lb.)
Install the enclosed identification label (F) to the valve body
where it can be seen.
Fill out the conversion label and attach it to the valve cover.
WARNING
Fire Risk.
Explosion Risk.
Gas Leak Risk.
• Rubber gasket must be seated properly on valve
face.
• Do no install a valve or regulator that has been
dropped.
WARNING
Fire Risk.
Explosion Risk.
If the information in these instructions is
not followed exactly, a fire, explosion or
production of carbon monoxide may result
causing property damage, personal injury
or loss of life.
The qualified service agency is responsible
for the proper installation of this conversion
kit. The installation is not proper and
complete until the operation of the converted
appliance is checked as specified in the
manufacturer's instructions supplied with
the kit.
Page 24
Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13
B. Gas Pressures
Proper input pressures required for optimum appliance per-
formance, gas line sizing requirements need to be followed
from NFPA54.
WARNING
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
WARNING
Verify inlet pressures.
• H i g h p r e s s u r e m a y c a u s e o v e r f i r e
condition.
• Low pressure may cause explosion.
Install regulator upstream of valve if line pressure
is greater than 1/2 psig.
Pressure requirements for appliance are shown in the table
below.
PRESSURE
Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure on "HI"
If the pressure is not sufficient, ensure:
1) the piping used is large enough.
2) the supply regulator is adequately adjusted.
3) that the total gas load for the residence does not exceed
the amount supplied.
The supply regulator (the regulator that attaches directly to the
residence inlet or to the propane tank) should supply gas at
the suggested input pressure listed above. Contact the local
gas supplier if the regulator is at an improper pressure.
NG
LP
4.5 inches w.c.
11.0 inches w.c.
7.0 inches w.c.
14.0 inches w.c.
3.5 inches w.c.
10.0 inches w.c.