3
Appliance Location and Clearances
NOTE:
·
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
·
Illustrations/diagrams are not drawn to scale.
·
Actual installation may vary due to individual design
preference.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (see Figure 3.1).
NOTE: For actual appliance dimensions refer to Sec-
tion 12.
B. Clearances
A
E
Hudson Bay
Figure 3.1
It is permissible to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
D
B
A
C
E
Model
9-5/8
Inches
Millimeters
Quadra-Fire • Hudson Bay • 7003-121 Rev. Q • 8/13
F
A
B
C
D
1
36
46-1/2
219
25
91
118
WARNING
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffic areas.
WARNING
Fire Risk.
Locate and install appliance to all
clearance specifications in manual.
F
G
E
F
G
9
4
54
21
229
102
137
533
WARNING
Fire Risk.
Odor Risk.
Tipping Risk
Install appliance on a stable, level platform/
floor strong enough to support appliance
without tipping.
USE wood flooring, ceramic tile, brick hearth
or high pressure laminate flooring applied
directly over the sub-flooring material.
H
H