INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
CLASSIC BAY 1200 PELLET
APPLIANCE
MODEL:
CB1200-C
CAUTION
Tested and approved for wood pellets and shelled field
corn fuel only. Burning of any other type of fuel voids
your warranty.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
R
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal injury,
or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void
your warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fireplace.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, fire officials or authorities
having jurisdiction about restrictions, installation
inspection, and permits.
NOTE: To obtain a French translation of this
manual, please contact your dealer or visit
www.quadrafire.com
REMARQUE : Pour obtenir une traduction française de
ce manuel, s'il vous plaît contacter votre
revendeur ou visitez
7027-801C
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
CAUTION
www.quadrafire.com
June 4, 2019

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire CLASSIC BAY 1200

  • Page 1 INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING CLASSIC BAY 1200 PELLET If the information in these instructions is not followed exactly, a fire could result APPLIANCE causing property damage, personal injury, or death.
  • Page 2: Table Of Contents

    F. Equivalent Feet of Pipe ..... .16 G. Pipe Selection Chart ......16 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7027-801C...
  • Page 3: Important Safety Information

    ‡ Grade of pellet fuel as certified by Pellet Fuels Institute (PFI), ENPlus or CANplus. This Classic Bay 1200 is Certified to comply with 2020 particulate emission standards. This pellet appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate this pellet appliance in a manner inconsistent with operating instructions in this manual.
  • Page 4: Glass Specifications

    CB1200 Free Standing I. California - Prop65 C. Glass Specifications This appliance is equipped with 5mm ceramic glass. WARNING Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. This product and the fuels used to operate this product (wood), and the products of combustion of such fuels, can expose you to D.
  • Page 5: Getting Started

    CB1200 Free Standing Install Guide Getting Started A. Design, Installation & Location Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: Considerations Windows 1. Appliance Location Air Intakes NOTICE: Check building codes prior to installation. Air Conditioner Overhang, soffits, porch roofs, adjacent walls •...
  • Page 6: Thermostat Wall Control Location

    CB1200 Free Standing B. Thermostat Wall Control Location WARNING The thermostat wall control’s location will have some affect on the appliance’s operation. • Maximum wire length from appliance is 100 feet Risk of Fire! • Damaged parts could impair safe (30.48m) continuous non-spliced wire.
  • Page 7: Install Checklist

    CB1200 Free Standing E. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. __________________________________________________________________________ Customer: ______________________________________________________________________ Date Installed: _______________________________________________________________________ Lot/Address:...
  • Page 8: Dimensions And Clearances

    CB1200 Free Standing Dimensions and Clearances A. Appliance Dimensions 14-1/4 [362] 6-1/4 [203] [203] [159] [127] 3-5/8 2-3/8 [62] [94] Figure 8.1 - Top View Figure 8.4 - Top View with Top Vent Adapter (TPVNT-1) and Offset Adapter (812-3570) 27-5/8 [702] 25-3/4 [654] 33-3/8 [847]...
  • Page 9 CB1200 Free Standing 33-1/8 [841] 31-1/4 [795] 15-51/8 [398] [357] Figure 9.1 - Side View with Top Vent Adapter (TPVNT-1) and Figure 9.3 - Side View with Top Vent Adapter (TPVNT-6) and Offset Adapter (811-0720) Offset Adapter (811-0720) 6-1/4 [203] [203] [159] 3-7/8...
  • Page 10: Clearances To Combustibles (Ul And Ulc)

    CB1200 Free Standing B. Clearances to Combustibles (UL and ULC) Installations with: TPVNT-1 Top Vent Adapter with Heat Shield and Clean-out TPVNT-6 Top Vent Adapter with Clean-out 811-0720 (3” to 4”) Offset Adapter 812-3570 (3” to 6”) Offset Adapter Horizontal Through the Wall Inches Millimeters Back Wall to Appliance...
  • Page 11: Hearth Pad Requirements (Ul And Ulc)

    CB1200 Free Standing C. Hearth Pad Requirements (UL and ULC) USA INSTALLATIONS: A non-combustible floor protection is recommended extending beneath the flue pipe when EMBER PROTECTION: It is necessary to install a Type I installed with horizontal venting or under the Top Vent floor protector.
  • Page 12: Alcove

    CB1200 Free Standing D. Alcove Figure 12.2 Figure 12.1 Minimum* Maximum Inches Millimeters Inches Millimeters Height 1117 Width 40.5 1029 Depth To Side Wall *All minimums listed are to a combustible surface. NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.
  • Page 13: Vent Information

    CB1200 Free Standing Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Figure 13.1 Termination Cap Air Supply Inlet Restricted Area Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 14: Avoiding Smoke And Odors

    CB1200 Free Standing Vent Configurations B. Avoiding Smoke and Odors When installing a pellet appliance with a horizontal vent Negative Pressure, Shut-Down and Electrical configuration the frequency of power outages should Power Failure be considered: To reduce the probability of back-drafting or burn-back •...
  • Page 15: Negative Pressure

    CB1200 Free Standing D. Negative Pressure E. Chimney and Exhaust Connection 1. Chimney & Connector: Use 3 or 4 inch (76-102mm) WARNING diameter type “L” or “PL” venting system. It can be vented vertically or horizontally. Risk of Asphyxiation! NOTE: The appliance exhaust outlet is designed to Negative pressure can cause spillage of combustion accommodate 3 inch venting.
  • Page 16: Equivalent Feet Of Pipe

    CB1200 Free Standing F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size (Figure 16.1). Vent surfaces get HOT, can cause burns if touched.
  • Page 17: Venting Systems

    CAN/CSA-B365. installations. Must use 3 or 4 inch (76-102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and a Quadra-Fire Outside Air Kit in mobile homes. CAUTION NOTICE: Please note that while the minimum clearance...
  • Page 18: Vertical Into Existing Class A Chimney

    CB1200 Free Standing B. Vertical into Existing Class A Chimney All three installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and Quadra- Rain Cap Fire Outside Air Kit in mobile homes.
  • Page 19: Masonry

    CB1200 Free Standing WARNING Fire Risk. Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211. • Factory-built chimney must be a minimum 6 inch (152mm) UL103 HT. E. Masonry Fireclay Flue Concrete Cap Liner with Airspace Flashing...
  • Page 20: Appliance Set-Up

    CB1200 Free Standing Appliance Set-Up A. Outside Air Kit Instructions 2. Floor Installation a. Remove rear screen and set aside. Included in Kit: 1 piece of 2 inch x 3 foot flex hose, 2 hose b. Install cover plate over hole in right rear floor. clamps, 1 collar assembly, termination cap assembly, 1 trim c.
  • Page 21: Top Vent Adapter Installation

    CB1200 Free Standing B. Top Vent Adapter Installation C. Rear Vent & Rear Vent to Top Vent Adapter 1. Put a layer of high temp silicone on the 3 inch (76mm) 3 to 3 inch Top Vent Adapter exhaust outlet. 3 to 6 inch Top Vent Offset Adapter 2.
  • Page 22 CB1200 Free Standing CAUTION NOTE: Ensure bare wire ends are held ALL the way into the terminal block while the screws are being tightened. Shock hazard. • Do NOT remove grounding prong 6. There are two AA ALKALINE ONLY batteries from plug.
  • Page 23: Optional Log Set Placement Instructions

    CB1200 Free Standing E. Optional Log Set Placement Instructions F. Installing Logo 1. Place the front log in first as shown in Figure 23.1. 1. Remove logo from packaging. Place log between fire pot and face of appliance with 2. The logo has 2 studs on the back. charred area surrounding fire pot.
  • Page 24: Mobile Home Installation

    CB1200 Free Standing Mobile Home Installation You must use a Quadra-Fire Outside Air Kit for CAUTION installation in a mobile home. 1. An outside air inlet must be provided for the THE STRUCTURAL INTEGRITY OF THE MOBILE combustion air and must remain clear of leaves, debris, HOME FLOOR, WALL AND CEILING/ROOF MUST ice and/or snow.
  • Page 25: Accessory List

    CB1200 Free Standing Accessory List A. Service & Maintenance Log Date of Service Performed By Description of Service June 4, 2019 7027-801C...
  • Page 26: Accessory List

    Snap Disc, Manual Reset ( #3 ) SRV230-1290 Panel, Rear Access, Top 410-4352 CB1200 Free Standing Vacuum Switch SRV7000-531 B. Accessory List Hose, Vacuum, 5/32 Qty 3 ft req SRV240-0450 Control Board 3 Speed SRV7000-704 CB1200-C Service Parts Fuse, 8 Amp, Control Box Pkg of 10 812-3780/10 Beginning Manufacturing Date:March 2019...
  • Page 27: Service Parts

    CB1200 Free Standing CB1200-C Service Parts Beginning Manufacturing Date:March 2019 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. .
  • Page 28 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents