Read Time-Out
Use this selection to set a time-out (in milliseconds) of the imager's trigger when
using serial commands to trigger the imager. Once the imager has timed out,
you can activate the imager either by pressing the trigger or using a serial trigger
command. After scanning the Read Time-Out bar code, set the time-out
duration (from 0-300,000 milliseconds) by scanning digits from the inside back
cover, then scanning Save. Default = 300,000.
Read Time-Out

Automatic Trigger

The imager scans continuously at full power with illumination fully on.
Automatic Trigger

Presentation Mode

Presentation Mode uses ambient light to detect bar codes. The LEDs are off for
ambient conditions until a change occurs in the imager's field of view. Then the
LEDS turn on automatically to read the code. If the light level in the room is not
high enough, Presentation Mode may not work properly.
Presentation Mode

Continuous Illumination Mode

If you have several bar codes that are close together, you may wish to have a
continuous aiming beam on in order to properly aim the imager at one bar code.
Scan the Continuous Illumination On bar code to program the imager for this
capability. Once you have the aiming beam over the correct bar code, pull the
trigger to read the code. Scan the Continuous Illumination Off bar code to turn
off this feature.
Continuous Illumination Mode On
* Continuous Illumination Mode Off