Log Set Installation - FPI U32 Owners & Installation Manual

U32 gas insert
Hide thumbs Also See for U32:
Table of Contents

Advertisement

INSTALLATION
Read the instructions below carefully and refer to the images.
Dangerous operating conditions may occur if the logs are not
positioned in their correct locations. If the logs are broken
do not use the unit until they are replaced. Broken logs can
interfere with the pilot operation.
IMPORTANT
For LP units the Air Defl ector MUST be installed prior
to log installation. See "Conversion from NG to LP"
section in manual for installation instructions.
Log kit (Part # 425-930) contains the following pieces:
a)
27-31
Rear Log
b)
27-32
Middle Left Log
c)
27-33
Front Log
d)
27-34
Middle Right Log
e)
27-35
Left Log
f)
27-36
Right Log
g)
902-154
Embers Lava
h)
902-179
Vermiculite
i)
902-153
Rock Wool
j)
946-669
Platinum Embers
27-36
27-32
27-33
1) Carefully remove the logs from the box and unwrap them. The logs
are fragile, handle with care - do not force into position.
10

LOG SET INSTALLATION

(supplied with packaged manual)
27-35
27-34
27-31
2) Spread vermiculite around the exposed fi rebox base. Then take some
embers and spread them over the vermiculite as shown.
Vermiculite and Embers
3) Fit log 27-31 into the pins on the rear log tray.
27-31
4) Fit log 27-32 into the pins on the middle left hand side of the
burner.
27-32
U32-5 FPI Direct Vent Gas Insert