Fan Maintenance - FPI U32 Owners & Installation Manual

U32 gas insert
Hide thumbs Also See for U32:
Table of Contents

Advertisement

MAINTENANCE
Bay Glass Removal
1) Remove the door from the unit and place
on a soft surface to prevent scratching.
2) Remove the nuts holding the glass retainers
in place.
3) Remove the glass retainers (sides, top and
bottom).
4) Replace the glass. The glass must have
gasketing around it.
5) Reverse the previous steps, replace the
retainers and fasten with the nuts but do not
over tighten, as this can break the glass.
6) Replace door on the stove and check the
seal.

FAN MAINTENANCE

If your fan requires maintenance or replacement,
access to the fan is through the plate on the rear
wall of the fi rebox. NOTE: the unit MUST NOT
be operated without the fan access panel
securely in place.
Caution: Label all wires prior to
disconnecting when servicing controls.
Wiring errors can cause improper and
dangerous operation. Verify proper
operation after servicing.
32
TO REMOVE FAN:
1) Turn the unit off and allow it to cool to room
temperature.
2) Unplug or disconnect power source to
stove.
3) Remove glass front (see section "Standard
Flush Door.")
4) Remove logs and brick panels, if used.
5) Remove the grate by loosening the two
screws and sliding the grate out.
6) Remove the burner/front log support
assembly by removing the 2 screws and
lifting it out.
Grate screws
7) Remove the 2 screws holding the Air Intake
Hood to the rear fi rebox wall and lift out.
8) Remove the 10 screws holding the Access
Panel in place.
9) Remove the Fan Air Duct by loosening the
3 screws, squeeze the sides together to
remove.
10) Unplug the wires from the fan motor (from
inside the stove).
11) Lift Fan Assembly off of the 2 pins, tip forward
and pull through fi rebox opening.
12) Disconnect green wire from power cord.
Replacing fan:
Reverse above steps. Hint for pushing fan down
onto pins - rub a bit of dish soap on the grommet
so it will slide more easily onto the pin.
Check to make sure the fan is seated properly
on the pins, this is very important- try to move
the fan back and forth, there should be no noise,
if there is check that the grommets haven't
come loose.
Seal fan access panel using high temperature
silicone (sparingly).
U32-5 FPI Direct Vent Gas Insert

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U32-ng5U32-lp5

Table of Contents