Prime Condensate Trap With Water; Purge Gas Lines; Furnace Setup Switch Description; Blower Off Delay Setup Switch Position - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

Table9--FurnaceSetupSwitchDescription
SETUP
SWITCH
NORMAL
DESCRIPTION
SWITCH NO.
NAME
POSITION
OF USE
Turn ON to retrieve up to 7 stored status codes for trouNeshooting
SW14
Status Code Recovery
OFF
assistance when R thermostat lead is disconnected.
Mows 2-stage operation with a single stage thermostat
Turn ON when using 2 stage thermostat to allow Low Heat opera-
SWI-2
Adaptive Heat Mode
OFF
tion when R to W/W1 closes and High Heat operation when R to
W/W1 and W2 close.
Turn ON to increase Low Heat airflow by 18 percent This compen-
Low Heat
8W1_3
Rise Adjust
OFF
sates for increased return air temperature caused with bypass hu-
midifier
Turn ON to decrease Low Heat airflow by 7 percent and High Heat
SWI_4
Comfort/Efficiency Adjustment
ON
airflow 8 percent for maximum comfort. On 040 unit will decrease
Low-Heat Airflow 11 percent and High-Heat Airflow 10 percent.
8W1_5
CFM per ton adjust
OFF
Turn ON for 400 CFM per ton. Turn OFF for 350 CFM per ton
Turn ON to initiate Component Self-Test for troubleshooting assis-
8W1_¢
Component Self-Test
OFF
tance when R thermostat lead is disconnected
Turn OFF when Self-Test is completed.
Control blower Off Delay time Used in conjunction with SW1-8. See
8W1_7
Blower OFF delay
ON or OFF
Table 10.
Control blower Off Delay time Used in conjunction with SW1-7. See
8W1_8
Blower OFF delay
ON or OFF
Table 10.
Table 10--Blower
Off Delay Setup Switch
Position
DESIRED HEATBNG
MODE BLOWER
OFF DELAY (SEC}
90
120
t50
180
SETUP SWITCH (SW1o7 AND SWlo8} PosmoN
SW1-7
SW1-8
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Step
3--Prime
Condensate
Trap
With
Water
UNIT
MAY
NOT
OPERATE
Failure
to %llow
this caution
may result in intermittent
unit
operation
oi" per%m_ance
satisfaction
Condensate
trap must be PRIMED
or proper draining
may not
occur. The condensate
trap has 2 internal
chambers
which can
ONLY be primed by pouring
water into the inducer
&ain side
of condensate
trap.
1, Remove upper inducer housing drain connection
cap (See
Fig. 52,)
2, (onnect
field-supplied
1/2=in ID robe to upper inducer
housing &ain connection
3. Insert field=supplied funnel into robe.
4. Pour 1 quart of water into _kmnelimbe Water should mn
through inducer housing, overl]ll condensate trap, and flow
into open field drain. (See Fig. 53)
5. Remove t:imnel and robe fi'om inducer housing and replace
&ain connection cap and clamp.
Step
4--Purge
Gas Lines
If not previously
done_ purge
the lines after all connections
have
been
made and check
%r leaks.
3g
FIRE
AND
EXPLOSION
HAZARD
Failure to %llow this warning
could result
in a fire, explosion,
personal
inj_/ry, or death
Never purge a gas line into a combustion
chamber
Never test
for
gas
leaks
with
an open
flame
Use
a commercially
available
soap solution
made specifically
%r the detection
of
leaks to check
all connections.
Step
5--Sequence
of Operation
I
[TNIT MAY
NOT
OPERATE
Failure
to %ltow
this caution
may result
in intem_ittent
unit
operation,
Furnace
cmmoi
must
be grounded
[br proper
operation,
or
control
will
tock
out.
(ontrol
is
grounded
through
green yellow
wire routed
to gas valve
and burner
box screw
Using
schematic
diagram,
%llow
sequence
of operation
through
different
modes
(See Fig. 3I.) Read
and follow
wiring
diagram
carefidly.
NOTE:
If a power
interruption
occurs
during
a call for heat
(WiWI
or W Wl=and-W2),
the control
will
start
a 90-second
blower-only
ON period two seconds
afier power
is restored,
if the
thermostat
is still calling for gas heating.
The amber
LED light wilt
flash
code
12 during
the 90=second
period,
after which
the LED
will be ON continuous,
as long as no fitults are detected.
After the
90=second
period,
the
_./rnace
will
respond
to
the
thermostat
normally
The blower
door must
be installed
%r power
to be conducted
through
the blower
door
interlock
switch
ILK
to the
t'umace
control
(PU,
tIansfom_er
TRAN,
inducer
motor
IDM,
blower
motor
BLWM,
hot=sur_hce
igniter
HSI, and gas valve
GV.
SrNGLE=STAGE
THERMOSTAT
AND
TWO=STAGE
HEATING
(ADAPTIVE
MODE)
See Fig. 28 or 6I %r thermostat
connections
NOTE:
Low-heat=only
switch,
SWl-2,
selects
either
the
low-
heat=only
operation
mode
when
ON,
(see
item
2
below)
or
adaptive
heating
mode
when
OFF,
in response
to a call fbr heat.
(See Fig
32)
When the W2 thermostat
terminal
is energized,
it
will always
cause l',igl'>heat
operation
when
the R to W circuit
is