Opening Dimensions - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

A96283
Fig. 19--Floor
and Plenum Opening
Dimensions
FURNACE
(OR COiL
CASING
WHEN
USED)
FLOORING
SUBBASE
SHEET
METAL
PLENUM
--
FLOOR
--
OPENING
FURNACE
CD5OR
CK5
COILASSEMBLY
OR
KCAKC
COILBOX
FLOORING
SHEET
METAL._
PLENUM
__
FLOOR
__
OPENING
A96285
A96284
Fig. 20--Furnace,
Plenum, and Subbase
Fig. 21--Furnace,
Plenum, and Coil
Installed
on a Combustib{e
Floor
Assembly
or Coi! Box Installed
on a Combustible
Floor
Tab{e 1--Opening
Dimensions
(In.)
FURNACE
CASING
WIDTH
APPUCATION
C
Upftow Applications
16-5/8
Downflow Applications
on Non-Combustible
Flooring
16-1/2
17olt2
Downflow Applications
on Combustible
Flooring Using KGASB Subbase
16-3/4
Furnace with or without CD5 or CK5 Coil Assembly or KCAKC Coil Box
Downflow Applications
on Combustible
Ftooring NOT Using KGASB Subbase
16-1/2
Furnace with CD5 or CK5 Coil Assembly or KCAKC Coil Box
Upflow Applications
20-1/8
Downflow Applications
on Non-Combustible
Flooring
20
21
Downflow Applications
on Combustible
Flooring Using KGASB Subbase
20-1/4
Furnace with or without CD5 or CK5 Coil Assembiy or KCAKC Coil Box
Downflow Applications
on Combustible
Flooring NOT Using KGASB Subbase
20
Furnace with CD5 or CK5 Coit Assembly or KCAKC Coil Box
Upftow Applications
23-5/8
Downflow Applications
on Non-Combustible
Flooring
23-1/2
24o112
Downflow Applications
on Combustible
Flooring Using KGASB Subbase
23-3/4
Furnace with or without CD5 or CK5 Coil Assembly or KCAKC Coil Box
Downflow Applications
on Combustible
Ftooring NOT Using KGASB Subbase
23-1/2
Furnace with CD5 or CK5 Coil Assembly or KCAKC Coil Box
PLENUM OP_=N_NG
A
B
16
24-1/8
15-7/8
19
15-1/8
19
15-1/2
19
19-1/2
24-1/8
19-3/8
19
18-5/8
19
19
19
23
24-1/8
22-7/8
19
22-1/8
19
22-1/2
19
FLOOR OPENING
D
24-3/4
19-5/8
20-3/8
20
24-3/4
19-5/8
20-3/8
20
24-3/4
19-5/8
20-3/8
20
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents