Start-Up, Adjustment And Safety Check; Select Setup Switch Positions; Condensate Drain Protection; Air Conditioning (A/C) Setup Switches - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

/
\
OPEN STAND
--7
PIPE FOR ]
A/C OR
/
HUMIDIFIER
,_
DRAIN
_
A94054
Fig. 48--Example
of Fiemd Drain Attachment
APPLI(ATION
The fb.mace,
A/C,
and humidifier
&ains
may be combined
and
drained
together.
The Ai(
&ain
must
have
an external,
t_eld°
supplied
trap prior
to the
furnace
&ain
connection
All
&ain
connections
(furnace,
A/C, or humidifier)
must be terminated
into
an open
or vented
drain
as close
to the respective
equipment
as
possible
to prevent
siphoning
of the equipment's
&ain.
See Fig. 48 _br example
of possible
field drain attachment
using
1/2-in.
CPVC
or PVC
tee _br vent and AiC or humidifier
&ain
connection.
Outdoor
draining
of the Nrnace
is permissible
if allowed
by local
codes. ( aution
should be taken when
t?eezing
ambient
may freeze
drain pipe and prohibit
draining.
--€
PERSONAL
INJURY
AND
PROPERTY
DAMAGE
HAZARD
Failure to £_llow this warning
could result in property
damage
and personal
ir!iury or death.
(antion
should be taken to prevent
&aining
where
slippery
conditions
may cause personal
ir!iuries. Excessive
condensate
draining
may cause saturated
soil conditions
which may result
in damage
to plants.
4. Wrap field drain pipe with remaining
heat tape, approximately
1 wrap per ft
5. When using
field=supplied
heat tape, _bllow
heat tape manu=
_hcturer's
insm/ctions
for all other installation
guidelines.
START-UP,
ADJUSTMENTS
AND SAFETY
CHECK
Step
l--General
1. F_lrnace must have
a 115=v powei
supply
properly
connected
and grounded.
NOTE:
Proper
polarity
must
be maintained
for l15-v
wiring.
If
polarity
is incon'ect,
control
stares
indicator
light flashes
rapidly
and furnace
does not operate.
2. Thermostat
wire
connections
at terminals
R, W/W1,
G, and
Y/Y2 must be made at 24-v tem_inal
block
on furnace
control.
3. Natmal
gas service pressure
must
not exceed
0.5 psig (14-in.
wc), but must be no tess than 0.16 psig (4.5=in. wc).
4. Blower
access
panel
must
be in place
to complete
l15-v
electrical
circuit
to filrnace.
FIRE
HAZARD
Failure
to _bllow this cmltion
may resnlt
in intermittent
unit
operation
or per[brmance
satisfaction.
These t:urnaces
are equipped
with a manual
reset limit switch
in burner
box. This switch
opens and shuts off power
to the
gas valve
if an overheat
condition
(flame
rollout)
occurs
in
burner
enclosure.
(orrect
inadequate
combustion=air
supply
or improper
venting
condition
befbre
resetting
switch.
DO
NOT jmnper
this switch.
Be%re
operating
fire, ace, check flame rollout
manual
reset switch
for continuity.
If necessary,
press
button
to reset
switch
Step
2--Select
Setup
Switch
Positions
AIR (ONDITIONING
(A/C)
SETUP
SWIT(HES
The air conditioning
setup
switches
are used
to match
furnace
airflow
to cooling
unit used.
To set the desired
cooling
airflow:
1. Remove
main fi/mace
door and blower
access
panel,
2. Locate
AiC setup switches
on furnace
control,
(See Fig. 32)
3. Determine
air conditioning
tonnage
used,
CONDENSATE
( ONDENSATE
DRAIN
PROTECTION
Freezing
condensate
left in condensate
trap and drain
line may
cause
cracks,
and possible
water
damage
may
occur.
If freeze
protection
is required,
use condensate
t'reeze protection
accessow
or equivalent
3 to 6 watt per ft at 120v and 40°F self=regulating,
shielded,
and waterproof
heat tape.
See Installation
Instructions
supplied
with accessory
or heat tape manuitacturer's
recommenda°
tions
1. Fold heat tape in halt" and wrap on itself 3 times,
2. Locate
heat tape between
sides of condensate
trap back. (See
Fig. 49.)
3. [so
wire ties to secure
heat tape in place
Wire
ties can be
positioned
in notches
of" condensate
tlap sides
(See Fig. 49.)
36
WIRE
TIE(S)_
,4
HEAT TAPE_
(3 WRAPS
MINIMUM)_
Fig. 49--Condensate
Trap Heat Tape
A93036