Carrier 58MVP Product Data

Deluxe 4-way multipoise direct-vent variable-capacity condensing gas furnace

Advertisement

Copyright 1998 Carrier Corporation
Product
Data
Deluxe 4-Way Multipoise
Direct-Vent Variable-Capacity
Condensing Gas Furnace
Input Capacities: 40,000 thru 120,000 Btuh
Variable capacity,
the ultimate in
heating comfort . . .
With the model 58MVP
WeatherMaker
we've taken the ultimate in heating
comfort and made it better.
The model 58MVP is available in 6
heat/airflow combinations. The unit
has a 4-way multipoise design and can
be installed in upflow, downflow, or
horizontal positions covering up to
24 different applications.
The WeatherMaker Infinity achieves
industry-leading ultra-high efficiency
at up to 96.6 percent Annual Fuel
Utilization Efficiency (AFUE).
Efficient performance is enhanced
through the variable-capacity design.
To maintain ideal comfort, the control
system of the WeatherMaker Infinity
automatically adjusts, maximizing the
use of low operating speeds that
produce near silent furnace operation
while meeting the exact heating
needs. This unit is designed to keep
the indoor temperature within
1 degree of the thermostat setpoint.
Because it operates in low speed most
of the time, the model 58MVP uses
up to 80% less power than single-
capacity furnaces.
In addition to providing optimum
comfort, the model 58MVP has a
sealed combustion system. This
system brings combustion air from
outdoors to the furnace and vents
flue gases safely outside the home.
Because it is sealed, operational noise
is minimal. A sealed combustion
system also means fewer cold drafts
and less air infiltration.
Quality materials are the key behind
the model 58MVP's outstanding
performance. Carrier stands behind
58MVP
Series 130
TM
Infinity Furnace,
Form 58MVP-7PD

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 58MVP

  • Page 1 WeatherMaker Infinity Furnace, we’ve taken the ultimate in heating comfort and made it better. The model 58MVP is available in 6 heat/airflow combinations. The unit has a 4-way multipoise design and can be installed in upflow, downflow, or horizontal positions covering up to 24 different applications.
  • Page 2 Automatically shuts off 115-v power in conjunction with variable capacity before switching to high heat unless to furnace whenever blower access makes the 58MVP ideal for use with the room thermostat has been satisfied. panel is opened. split-system cooling, including Subsequent thermostat cycles provide 2-speed units.
  • Page 3 A96275 NOTES: 1. The 58MVP Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory-authorized and listed accessory conversion kit. 2. Control location and actual controls may be different than shown above.
  • Page 4: Model Number Nomenclature

    * Factory-authorized and field-installed. Gas conversion kits are A.G.A. recognized. † Required for installation on combustible floors when no coil box is used, or when any coil box other than a Carrier CD5, CK5, or KCAKC cased coil is used.
  • Page 5 One pipe runs inside the other Accepts one 16 x 25 x 1 in. filter. a Carrier cased coil is used. It allowing venting through the (Not included) is A.G.A. design certified for...
  • Page 6: Physical Data

    Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. As an ENERGY STAR Partner, Carrier Corporation has determined that this product meets the ENERGY STAR guidelines for energy efficiency. REGISTERED QUALITY SYSTEM These products are engineered and manufactured under an...
  • Page 7: Performance Data

    Performance data UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 DIRECT-DRIVE MOTOR Hp (ICM) MOTOR FULL LOAD AMPS 12.4 12.4 RPM (Nominal) — SPEEDS Variable 250 — 1300 BLOWER WHEEL DIAMETER x WIDTH (In.) 11 x 10 10 x 7 11 x 10 11 x 10 11 x 10...
  • Page 8 AIR DELIVERY — CFM (With Filter)* AND POWER DRAW (WATTS)** External Static Pressure (ESP) UNIT OPERATING AIRFLOW External Static SIZE MODE Pressure Range* 040-14 Power Draw (WATTS)** Low Heat 565 (650†) 0–0.26 — — — — — High Heat 0–0.49 —...
  • Page 9 AIR DELIVERY CURVE — 040-14 AIR DELIVERY CURVE — 060-14 HIGH HEAT Constant System Constant System Curves Curves HIGH HEAT HEAT HEAT ⁄ ⁄ ⁄ 2 Ton ⁄ 3 Ton ⁄ 2 Ton ⁄ 3 Ton 1000 1100 1200 1300 1400 1500 1000...
  • Page 10: Condensate Trap

    Dimensions CONCENTRIC VENT B IN. DIA PVC VENT/EXHAUST C IN. DIA 1 /2 B IN. DIA PVC INTAKE/COMBUSTION AIR A97110 DIMENSIONS (in.) KIT PART NO. D† KGAVT0501CVT 33-3/8 3-1/2 16-5/8 6-1/4 5-3/4 KGAVT0601CVT 38-7/8 4-1/2 21-1/8 7-3/8 6-1/2 * Dimension A will change accordingly as dimension D is lengthened or shortened. †...
  • Page 12 DOWNFLOW SUBBASE — DIMENSIONS (In.) FURNACE PLENUM OPENING* FLOOR OPENING HOLE NO. CASING FURNACE IN DOWNFLOW APPLICATION FOR WIDTH WIDTH ADJUSTMENT Furnace with or without CD5 or CK5 Coil 17-1/2 15-1/8 16-3/4 20-3/8 Assembly or KCAKC Coil Box Furnace with or without CD5 or CK5 Coil 18-5/8 20-1/4 20-3/8...
  • Page 13: Electrical Data

    Electrical data UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 UNIT VOLTS — HERTZ — PHASE 115 — 60 — 1 OPERATING VOLTAGE RANGE (Min — Max) 104 — 127 MAXIMUM UNIT AMPS 13.8 13.8 11.6 UNIT AMPACITY† 12.0 12.0 12.0 17.9 18.1...
  • Page 14 Combustion-air and vent piping MAXIMUM ALLOWABLE PIPE LENGTH (FT) ALTITUDE PIPE DIA NUMBER OF 90° ELBOWS ABOVE SEA UNIT SIZE TERMINATION TYPE (IN.)* LEVEL (FT) 1-1/2 040-14 2 Pipe or 2-In. Concentric 1-1/2 060-14 2 Pipe or 2-In. Concentric 1-1/2 080-14 2 Pipe or 2-In.
  • Page 15 MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued ALTITUDE NUMBER OF 90° ELBOWS ABOVE SEA PIPE DIA LEVEL (FT) UNIT SIZE TERMINATION TYPE (IN.)* 1-1/2 040-14 2 Pipe or 2-In. Concentric 1-1/2 060-14 2 Pipe or 2-In. Concentric 6001 to 7000‡ 1-1/2 080-14 2 Pipe or 2-In.
  • Page 16 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* INSULATION THICKNESS (IN.)† WINTER DESIGN MAX PIPE DIA UNIT SIZE TEMP °F (IN.) 040-14 - 20 060-14 - 20 080-14 080-20 - 20 2-1/2 100-20 2-1/2 - 20 2-1/2 120-20...
  • Page 17: Clearance To Combustibles

    Clearance to combustibles This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size Furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
  • Page 18: Typical Installations

    Typical installations COMBUSTION AIR PIPE OUTDOOR UNIT VENT PIPE A/C COIL HUMIDIFIER GAS-FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW Basement — Upflow Application A93063 ELECTRONIC AIR CLEANER VENT COMBUSTION HUMIDIFIER OUTDOOR UNIT A/C COIL AIRFLOW Closet — Downflow Application A93064...
  • Page 19 COMBUSTION–AIR PIPE VENT PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN AIR CONDITIONING COIL REFRIGERATION PIPING AIRFLOW Attic — Horizontal Application A93065 COMBUSTION– AIR PIPE VENT PIPE REFRIGERATION PIPING AIR CONDITIONING COIL ELECTRONIC AIR CLEANER AIRFLOW FURNACE CONDENSATE DRAIN Crawlspace — Horizontal Application A93066...
  • Page 20 [ ] Packaged Service Training [ ] Classroom Service Training A94328 • Copyright 1998 Carrier Corporation Indianapolis, IN 46231 11-98 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents