Condensate Trap Freeze Protection; Horizontal Left (Supply-Air Discharge) Application - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

Relocate robes as described below,
1. Disconnect
collector
box pressure
tube (pink label) attached
to
pressure
switch.
2. Extend
collector
box pressure
tube (green
label) which
was
previously
connected
to condensate
trap relief port connection
by splicing
to small
diameter
robe (factoD'-supplied
in loose
parts
bag).
3. Connect
collector
box pressure
tube (green
label) to pressure
switch
connection
labeled
COLLECTOR
BOX.
4. Extend
collector
box
pressure
tube (pink
label)
which
was
previously
connected
to pressure
switch by splicing
to remain°
ing small diameter
robe (factoD'-supplied
in loose parts bag)
5. Route this extended
robe (pink label) to condensate
t_ap relief
port connection.
6. Determine
appropriate
length,
cut, and connect
robe.
7. (lamp
robe to relief port connection.
( ONDENSATE
TRAP FREEZE
PROTE(
TION
Refkr
to Condensate
Drain
Protection
section
%r recommenda-
tions
and procedures.
Step
4--Horizontal
Left (Supp[yoAir
Discharge)
Applications
A horizontal
left furnace
application
is where
t_urnace blower
is
located
to the right of combustion
and controls
section
of furnace,
and conditioned
air is discharged
to the left.
--€
2
0
_
MINOR
PROPERTY
DAMAGE
Failure
to fbllow
this caution
may result
in minor
property
damage.
Local codes may require
a drain pan under entire furnace
and
condensate
trap when a condensing
f_lrnace is used in an attic
application
or over a finished
ceiling.
NOTE:
In Canada,
installations
shall
be
in
accordance
with
cmxent
NS(NGPIC
and/or
local codes.
CONDENSATE
TRAP LOCATION
The condensate
trap must
be removed
from the fhctow-installed
blowe* shelf'location
and relocated
in selected
application
location
as shown
in Fig
2or
11.
To relocate
condensate
trap
fi'om
the
blowe*
shelf
to desired
location,
perfbrm
the following:
1. Remove
3 tribes connected
to condensate
trap.
2. Remove
trap from blowe* shelf by gently
pushing
tabs inward
and rotating
trap.
3. Remove
casing hole filler cap fiom casing hole
(See Fig. 2 or
11)
4. Install
casing
hole filler
cap (fi_ctou-supplied
in toose parts
bag) into blower
shelf hole where
trap was removed
PLUG "-_
t
F
CAP
AUXILIARY
"J" BOX _
\
/
f--
COLLECTOR
BOX
\
\
/
/
DRAIN TUBE
/
/
(BLUE AND WHITE STRIPED)
CONOE S T
711
"\----\\
--CO ' CTO OOX
TRAP
\\\
XX
\
TUBE(GREEN)
LL_
\
\
\
\\
"--INDUCER
HOUSING
COLLECTOR
BOX _
N
N
\\
DRAIN TUBE (VIOLET)
EXTENSION
TUBE
X
X
X _COLLECTOR
BOX
....
C_%_L_E.C_T.gR
_
N
\
DRAIN TUBE (BLUE)
BOX EXTENSION
N
\
DRAIN TUBE
X
X
DRAIN TUBE COUPLING
_
\
COLLECTOR
BOX TUBE (PINK) --_
RELOCATE TUBE BETWEEN
BLOWER SHELF AND INDUCER HOUSING FOR
060, AND 080 HEATING INPUT FURNACES
Fig. 11--Horizontal
Left Tube Configuration
10
A02288