Supero SUPERSERVER 5018D-MF User Manual

Supero SUPERSERVER 5018D-MF User Manual

Superserver
Table of Contents

Advertisement

Quick Links

S
UPER
®
S
S
UPER
ERVER
5018D-MF
USER'S MANUAL
1.0

Advertisement

Table of Contents
loading

Summary of Contents for Supero SUPERSERVER 5018D-MF

  • Page 1 UPER ® UPER ERVER 5018D-MF USER’S MANUAL...
  • Page 2 The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
  • Page 3: About This Manual

    SuperServer 5018D-MF. Installation and maintenance should be performed by experienced technicians only. The SuperServer 5018D-MF is a high-end server based on the SC512F-350B 1U rackmount chassis and the Super X10SLL-F single processor motherboard.
  • Page 4 UPER ERVER 5018D-MF User's Manual Chapter 4: Standardized Warning Statements You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 5018D-MF. Chapter 5: Advanced Motherboard Setup Chapter 5 provides detailed information on the X10SLL-F motherboard, including the locations and functions of connections, headers and jumpers.
  • Page 5 Preface Notes...
  • Page 6: Table Of Contents

    UPER ERVER 5018D-MF User's Manual Table of Contents Chapter 1 Introduction Overview ......................1-1 Motherboard Features ..................1-2 Processors ...................... 1-2 Memory ......................1-2 Serial ATA ......................1-2 I/O Ports ......................1-2 Server Chassis Features ................1-3 Serial ATA Subsystem ..................1-3 Control Panel ....................
  • Page 7 Table of Contents NIC2 ........................ 3-2 NIC1 ........................ 3-2 HDD ......................... 3-3 Power ......................3-3 Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements ............4-1 Warning Defi nition ................... 4-1 Installation Instructions ..................4-4 Circuit Breaker ....................4-5 Power Disconnection Warning ................
  • Page 8 UPER ERVER 5018D-MF User's Manual 5-10 Onboard Indicators ..................5-24 5-11 SATA Drive Connections ................5-25 5-12 Installing Software ..................5-26 SuperDoctor III ....................5-27 5-13 Onboard Battery .................... 5-28 Chapter 6 Advanced Chassis Setup Static-Sensitive Devices .................. 6-1 Precautions ..................... 6-1 Control Panel ....................
  • Page 9: Chapter 1 Introduction

    Chapter 1 Introduction Overview The SuperServer 5018D-MF is a high-end server comprised of two main subsys- tems: the SC512F-350B 1U server chassis and the X10SLL-F single processor motherboard. Please refer to our web site for information on operating systems that have been certifi...
  • Page 10: Motherboard Features

    ERVER 5018D-MF User's Manual Motherboard Features At the heart of the SuperServer 5018D-MF lies the X10SLL-F, a single processor motherboard based on the Intel® C222 chipset. Below are the main features of the X10SLL-F (see Figure 1-1 for a block diagram of the chipset).
  • Page 11: Server Chassis Features

    The SC512F-350B is a short depth (14.5") 1U rackmount server chassis. The fol- lowing is a general outline of the main features of the SC512F-350B chassis. System Power When confi gured as the SuperServer 5018D-MF, the SC512F-350B chassis features a single power supply. Serial ATA Subsystem The SC512F-350B chassis is designed to support one internal SATA hard drive.
  • Page 12: System Block Diagram

    UPER ERVER 5018D-MF User's Manual Figure 1-1. Intel C222 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. #B-1 VR12.5 #B-0 3 PHASE #A-1 PCI-E X16 G3 #A-0 PCI-E x16 #0-15 Haswell-DT...
  • Page 13: Contacting Supermicro

    Chapter 1: Introduction Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel:...
  • Page 14 UPER ERVER 5018D-MF User's Manual Notes...
  • Page 15: Chapter 2 Server Installation

    Preparing for Setup The SuperServer 5018D-MF does not ship with a rack rail hardware package as the system can be rack mounted without the use of rails. An optional rack rail package is available if you wish to order from Supermicro. Follow the steps in the order given to complete the installation process in a minimal amount of time.
  • Page 16: Choosing A Setup Location

    UPER ERVER 5018D-MF User's Manual Choosing a Setup Location • Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
  • Page 17: Rack Mounting Considerations

    Chapter 2: Server Installation • Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling. Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room.
  • Page 18: Installing The System Into A Rack

    Note: the server may be installed as is - rack hardware is optional. Basic Installation Procedure The 5018D-MF server comes with two rack mounting brackets, which are located on each side at the front of the chassis. To mount the system into a rack, simply screw these brackets directly to the front of the rack (two screws for each bracket).
  • Page 19: Installing With Rackmount Kit

    Chapter 2: Server Installation Installing with Rackmount Kit This is a guideline for installing the unit into a rack with the optional rack kit (MCP- 290-00004-03). You should also refer to the installation instructions that came with the rack unit you are using. Be aware that there are a variety of rack units on the market, which may mean the assembly procedure will differ slightly.
  • Page 20 Figure 2-2. Installing Chassis Rails Installing the Rack Rails 1. Determine where you want to place the 5018D-MF in the rack (see Rack and Server Precautions in Section 2-3). 2. Position the fi xed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack.
  • Page 21 Chapter 2: Server Installation Figure 2-3. Installing the Server into a Rack (w/ Optional Rackmount Kit) Note: Figure is for illustrative purposes only. Always install servers into a rack starting at the bottom. Warning: do not pick up the server with the front handles. They are de- signed to pull the system from a rack only.
  • Page 22 Figure 2-4. Installing the Server into a Telco Rack Installing the Server into a Telco Rack If you are installing the SuperServer 5018D-MF into a Telco type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack.
  • Page 23: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c com- ponents.
  • Page 24: Control Panel Leds

    UPER ERVER 5018D-MF User's Manual Control Panel LEDs The control panel located on the front of the SC512F-520B chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
  • Page 25: Hdd

    Chapter 3: System Interface Channel activity for HDDs. This light indicates IDE drive activity when fl ashing. Power Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
  • Page 26 UPER ERVER 5018D-MF User's Manual Notes...
  • Page 27: Chapter 4 Standardized Warning Statements For Ac Systems

    Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance.
  • Page 28 UPER ERVER 5018D-MF User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 29 Warning Statements for AC Systems ‫ﺟﺴﺪﻳﺔ‬ ‫ﺍﺻﺎﺑﺔ‬ ‫ﺗﺘﺴﺒﺐ ﻓﻲ‬ ‫ﺣﺎﻟﺔ ﻳﻤﻜﻦ ﺃﻥ‬ ‫ﺍﻧﻚ ﻓﻲ‬ ‫ﺧﻄﺮ‬ ‫ﻳﻌﻨﻲ‬ ‫ﻫﺬﺍ ﺍﻟﺮﻣﺰ‬ !‫ﺗﺤﺬﻳﺮ‬ ‫ﺍﻟﺪﻭﺍﺋﺮ‬ ‫ﺑﺎﻟﻤﺨﺎﻁﺮ ﺍﻟﻨﺎﺟﻤﺔ ﻋﻦ‬ ‫ﻦ ﻋﻠﻰ ﻋﻠﻢ‬ ، ‫ﻛ‬ ‫ﻣﻌﺪﺍﺕ‬ ‫ﺗﻌﻤﻞ ﻋﻠﻰ ﺃﻱ‬ ‫ﻗﺒﻞ ﺃﻥ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫ﺣﻮﺍﺩﺙ‬ ‫ﺃﻱ‬ ‫ﻭﻗﻮﻉ‬ ‫ﻤﻨﻊ‬ ‫ﻟ‬ ‫ﺍﻟﻮﻗﺎﺋﻴﺔ‬...
  • Page 30: Installation Instructions

    UPER ERVER 5018D-MF User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 31: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. 警告 此产品的短路(过载电流)保护由建筑物的供电系统提供,确保短路保护设备的额定电 流不大于250V,20A。 警告 此產品的短路(過載電流)保護由建築物的供電系統提供,確保短路保護設備的額定電 流不大於250V,20A。...
  • Page 32: Power Disconnection Warning

    UPER ERVER 5018D-MF User's Manual Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A. Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.
  • Page 33 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
  • Page 34: Equipment Installation

    UPER ERVER 5018D-MF User's Manual Equipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifi ziertem Personal gestattet werden.
  • Page 35: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalifi ceerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 36: Battery Handling

    UPER ERVER 5018D-MF User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .('‫כלי אבטחה בלבד )מפתח, מנעול וכד‬ ‫ﻣﺤﻈﻮﺭﺓ‬ ‫ﻣﻨﺎﻁﻖ‬ ‫ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ‬ ‫ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺗﺨﺼﻴﺺ‬ ‫ﺗﻢ‬ ،‫ﺃﺩﺍﺓ ﺧﺎﺻﺔ‬ ‫ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ‬...
  • Page 37 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 38: Redundant Power Supplies

    UPER ERVER 5018D-MF User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 39: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺑﻮﺣﺪﺍﺕ‬ ‫ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ‬ ‫ﺠﻬﺎﺯ‬ ‫ﺍﻟ‬ ‫ﻳﻜﻮﻥ ﻟﻬﺬﺍ‬ ‫ﻗﺪ‬ ‫ﺍﻟﻜﻬﺮﺑﺎء‬ ‫ﻋﻦ‬ ‫ﻮﺣﺪﺓ‬ ‫ﺍﻟ‬ ‫ﻟﻌﺰﻝ‬ ‫ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ‬ ‫ﻳﺠﺐ ﺇﺯﺍﻟﺔ‬ Waarschuwing Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken. Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is...
  • Page 40: Comply With Local And National Electrical Codes

    UPER ERVER 5018D-MF User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫ﺍﻟﻠﻮﺣﺔ‬ ‫ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ‬ ‫ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ‬ ‫ﻣﻦ‬ ‫ﺧﻄﺮ‬ ‫ﻫﻨﺎﻙ‬ ‫ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ‬ ‫ﺧﺪﻣﺔ‬ ‫ﻛﻦ ﺣﺬﺭﺍ ﻋﻨﺪ‬ ‫ﻳﻌﻤﻞ‬ ‫ﺍﻟﻨﻈﺎﻡ‬ ‫ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ‬...
  • Page 41: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫ﺍﻟﻤﺘﻌﻠﻘﺔ‬ ‫ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ‬ ‫ﻘﻮﺍﻧﻴﻦ‬ ‫ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬...
  • Page 42: Hot Swap Fan Warning

    UPER ERVER 5018D-MF User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
  • Page 43 Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 44: Power Cable And Ac Adapter

    UPER ERVER 5018D-MF User's Manual Power Cable and AC Adapter Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certifi...
  • Page 45 Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifi...
  • Page 46 UPER ERVER 5018D-MF User's Manual Notes 4-20...
  • Page 47: Chapter 5 Advanced Motherboard Setup

    Chapter 5: Advanced Motherboard Setup Chapter 5 Advanced Motherboard Setup This chapter covers the steps required to install processors and heatsinks to the X10SLL-F motherboard, connect the data and power cables and install add-on cards. All motherboard jumpers and connections are described and a layout and quick reference chart are included in this chapter.
  • Page 48: Processor And Heatsink Installation

    UPER ERVER 5018D-MF User's Manual Processor and Heatsink Installation Notes: • Always connect the power cord last and always remove it before adding, re- moving or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink.
  • Page 49 Chapter 5: Advanced Motherboard Setup 5. Align the CPU key, which is a semi- circle cutout, against the socket CPU Key key, which is the notch below the gold color dot on the side of the socket. 6. Align pin 1 of the CPU against pin 1 of the CPU socket.
  • Page 50: Installing A Passive Cpu Heatsink

    UPER ERVER 5018D-MF User's Manual Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the motherboard and the heatsink bracket underneath.
  • Page 51 Chapter 5: Advanced Motherboard Setup Figure 5-1. Installing the Heatsink Figure 5-2. Removing the Heatsink Loosen screws in the Screw #4 sequence shown Screw #1 Screw #2 Motherboard Screw #3...
  • Page 52 UPER ERVER 5018D-MF User's Manual Figure 5-1. Installing the Heatsink Figure 5-2. Removing the Heatsink Screw #4 Loosen screws in the sequence shown Screw #1 Screw #2 Motherboard Screw #3...
  • Page 53: Connecting Cables

    Chapter 5: Advanced Motherboard Setup Connecting Cables Now that the processors are installed, the next step is to connect the cables to the motherboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed in preconfi...
  • Page 54: I/O Ports

    UPER ERVER 5018D-MF User's Manual Figure 5-1. Front Control Panel Header Pins (JF1) Ground FP PWRLED 3.3 V HDD LED UID Switch NIC1 Activity LED 3.3V Stby 3.3V Stby NIC2 Activity LED OH/Fan Fail Blue LED Power Fail LED 3.3V...
  • Page 55: Installing Memory

    Chapter 5: Advanced Motherboard Setup Installing Memory Note: Check the Supermicro web site for recommended memory modules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Installing DIMMs 1. Insert the desired number of DIMMs into the memory slots, starting with slot DIMMA1.
  • Page 56 UPER ERVER 5018D-MF User's Manual Towards the CPU Slot A1 (Blue Slot) Slot A2 Slot B1 (Blue Slot) Slot B2 Towards the edge of the motherboard Populating these DIMM modules with a pair of memory modules of the same type and same size will result in interleaved memory, which will improve memory performance.
  • Page 57 Chapter 5: Advanced Motherboard Setup Possible System Memory Allocation & Availability Physical Memory Remaining (-Available) System Device Size (4 GB Total System Memory) Firmware Hub fl ash memory (System BIOS) 1 MB 3.99 Local APIC 4 KB 3.99 Area Reserved for the chipset 2 MB 3.99 I/O APIC (4 Kbytes)
  • Page 58: Adding Pci Cards

    UPER ERVER 5018D-MF User's Manual Adding PCI Cards PCI Expansion Slots One riser card is used to support a PCI expansion (add-on) card in the system. The SC512F chassis can accommodate one standard size (full height full length) PCI expansion card. When viewed from the chassis front, the card installs to the left rear of the system.
  • Page 59: Motherboard Details

    Chapter 5: Advanced Motherboard Setup Motherboard Details Figure 5-4. SUPER X10SLL-F Layout USB6/7 COM1 COM2 USB4/5 LED1 BMC FW LAN1 LAN2 CTRL IPMI_LAN BIOS JPL2 JPL1 X10SLM-F/X10SLL(-F/SF/S) Rev. 1.02 IPMI Code BAR Code MAC Code T-SGPIO1 T-SGPIO2 I-SATA3 JSD1 I-SATA0 JBT1 JSTBY1 JPME1...
  • Page 60 UPER ERVER 5018D-MF User's Manual Jumper Description Default C1/JI SMB to PCI Slots Off (Disabled) JPB1 BMC Enable Pins 1-2 (Enabled) JBR1 BIOS Recovery Pins 1-2 (Normal) JPG1 VGA Enable Pins 1-2 (Enabled) JPL1/JPL2 LAN1/LAN2 Enable Pins 1-2 (Enabled) JPME1...
  • Page 61: Connector Defi Nitions

    Chapter 5: Advanced Motherboard Setup Connector Defi nitions ATX Power 24-pin Connector Pin Defi nitions (JPW1) Pin# Defi nition Pin # Defi nition Power Connectors +3.3V +3.3V The 24 - pin main power connector -12V +3.3V (JPW1) is used to provide power to the motherboard.
  • Page 62 UPER ERVER 5018D-MF User's Manual NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located LAN1/LAN2 LED Pin Defi nitions (JF1) on pins 11 and 12 of JF1, and the LED Pin# Defi nition connection for LAN Port 2 is on pins 9 9/11 3.3V Stby...
  • Page 63 Chapter 5: Advanced Motherboard Setup Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily Power Button Pin Defi nitions (JF1) contacting both pins will power on/off the Pin# Defi nition system. This button can also be confi g- ured to function as a suspend button (see Signal BIOS Setup).
  • Page 64 UPER ERVER 5018D-MF User's Manual Fan Headers Fan Header Pin Defi nitions The X10SLL-F has five fan headers Pin# Defi nition (Fan1 ~ Fan4 and FanA). These are 4-pin Ground (Black) fan headers and work with IPMI to moni- +12V (Red)
  • Page 65 Chapter 5: Advanced Motherboard Setup Trusted Platform Module Header Trusted Platform Module Header Pin Defi nitions This header is used to connect a Trusted Pin # Defi nition Pin # Defi nition Platform Module (TPM), available sepa- LCLK rately from a third-party vendor. A TPM is LFRAME No Pin a security device that allows encryption...
  • Page 66 UPER ERVER 5018D-MF User's Manual T-SGPIO 1/2 & 3-SGPIO 1/2 Headers Serial_Link-SGPIO Pin Defi nitions Two T-SGPIO (Serial-Link General Pur- Pin# Defi nition Defi nition pose Input/Output) headers are provided on the motherboard. These headers are Ground DATA Out used to communicate with the enclosure...
  • Page 67: Jumper Settings

    Chapter 5: Advanced Motherboard Setup Jumper Settings Explanation of Jumpers To modify the operation of the mother- board, jumpers can be used to choose Connector between optional settings. Jumpers cre- Pins ate shorts between two pins to change the function of the connector. Pin 1 is Jumper identifi...
  • Page 68 UPER ERVER 5018D-MF User's Manual PCI Slot SMB Enable PCI Slot SMB Enable/Disable Jumper Settings Use Jumpers JI C1/JI C2 to enable PCI-E Setting Defi nition SMB (System Management Bus) support Closed Enabled to improve system management for the Open (Default) Disabled PCI-E slots.
  • Page 69 Chapter 5: Advanced Motherboard Setup Management Engine (ME) Recovery Use Jumper JPME1 to select ME Firmware Recovery mode, which will ME Recovery limit resource allocation for essential Jumper Settings system operation only in order to Jumper Setting Defi nition maintain normal power operation and Pins 1-2 Normal (Default) management.
  • Page 70: 5-10 Onboard Indicators

    UPER ERVER 5018D-MF User's Manual 5-10 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the LAN LED VGA port) have two LEDs. On each Giga- Connection Speed Indication bit LAN port, one LED indicates activity LED State Defi nition...
  • Page 71: 5-11 Sata Drive Connections

    Chapter 5: Advanced Motherboard Setup 5-11 SATA Drive Connections SATA Port Pin Defi nitions Pin # Defi nition SATA Ports Ground Two SATA 3.0 and four SATA 2.0 ports are included on the motherboard. See the table on the right for pin defi nitions for the Ground onboard SATA ports.
  • Page 72: 5-12 Installing Software

    UPER ERVER 5018D-MF User's Manual 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO fi...
  • Page 73: Superdoctor Iii

    Chapter 5: Advanced Motherboard Setup SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program allows you to monitor the environment and operations of your system.
  • Page 74: 5-13 Onboard Battery

    UPER ERVER 5018D-MF User's Manual Figure 5-7. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/soft- ware/SuperDoctorIII.cfm. For Linux, we recommend that you use the SuperDoctor II application instead.
  • Page 75: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC512F-350B chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
  • Page 76: Control Panel

    UPER ERVER 5018D-MF User's Manual Unpacking The motherboard is shipped in antistatic packaging to avoid static damage. When unpacking the board, make sure the person handling it is static protected. Figure 6-1. Chassis Views DVD-ROM Drive (Optional) Control Panel Power Supply...
  • Page 77: System Fans

    Chapter 6: Advanced Chassis Setup System Fans The 5018D-MF employs two sets of 4-cm counter-rotating fans to provide cooling. Each fan unit is made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airfl ow and works to dampen vibration levels.
  • Page 78: Drive Bay Installation/Removal

    Note: The DVD drive is optional and does not come pre- installed in the system. Only a "slim" DVD-ROM will fi t in the 5018D-MF. Accessing the Inside of the System 1.
  • Page 79: Dvd-Rom Drive Installation

    The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay. The DVD-ROM must have a "slim" profi le to fi t into the 5018D-MF. If you cannot remove the top cover with the system remaining in the rack, follow the procedure below.
  • Page 80 UPER ERVER 5018D-MF User's Manual 3. Carefully lift the server out of the rack. 4. Open the cover by following the procedure described on page 6-4. 5. Remove the screws that secure the DVD-ROM drive to the chassis and then lift the drive out of the chassis.
  • Page 81: Power Supply

    Chapter 6: Advanced Chassis Setup Power Supply The 5018D-MF has a single 350 watt power supply. This power supply has the capability of operating at a 100 or 240 input voltage. You must power down the system and then unplug the AC power cord to completely remove power from the system before removing the power supply.
  • Page 82 UPER ERVER 5018D-MF User's Manual 5. Reconnect the power cord, replace the chassis top cover and push the unit back into the rack. 6. Finish by turning on the power switch on the power supply, then depress the power button on the front of the system.
  • Page 83: Chapter 7 Bios

    Chapter 7: BIOS Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup Utility for the X10SLM-F/X10SLL-F/ X10SLL-SF/X10SLL-S . The ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
  • Page 84: How To Start The Setup Utility

    UPER ERVER 5018D-MF User's Manual How to Start the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens.
  • Page 85 Chapter 7: BIOS The following Main menu items will be displayed: System Time/System Date Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard. Press the <Tab>...
  • Page 86: Advanced Setup Confi Gurations

    UPER ERVER 5018D-MF User's Manual Advanced Setup Confi gurations Use the arrow keys to select Boot Setup and press <Enter> to access the submenu items: Warning: Take Caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency or an incorrect DRAM timing setting may cause system to become unstable.
  • Page 87 Chapter 7: BIOS Bootup Num-Lock This feature selects the Power-on state for the Numlock key. The options are Off and On. Wait For 'F1' If Error This feature forces the system to wait until the 'F1' key is pressed if an error oc- curs.
  • Page 88 UPER ERVER 5018D-MF User's Manual  CPU Confi guration The following CPU information will be displayed: • Type of CPU • CPU Signature • Microcode Patch • Maximum CPU Speed • Minimum CPU Speed • CPU Speed • Processor Cores •...
  • Page 89 Chapter 7: BIOS Hyper-threading Select Enabled to support Intel Hyper-threading Technology to enhance CPU per- formance. The options are Enabled and Disabled. Active Processor Cores This feature determines how many CPU cores will be activated for each CPU. When all is selected, all cores in the CPU will be activated. (Please refer to Intel's web site for more information.) The options are All, 1, 2, and 3.
  • Page 90 UPER ERVER 5018D-MF User's Manual CPU AES Select Enable to enable Intel CPU Advanced Encryption Standard (AES) Instruc- tions for CPU to enhance data integrity. The options are Enabled and Disabled. EIST EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency in an effort to reduce power consump- tion and heat dissipation.
  • Page 91 Chapter 7: BIOS 1-Core Ratio Limit (Available when "Turbo Mode" is set to Enabled) This increases (multiplies) 1 clock speed in the CPU core in relation to the bus speed when one CPU core is active. Press "+" or "-" on your keyboard to change this value.
  • Page 92 UPER ERVER 5018D-MF User's Manual CPU C3 Report (Available when "CPU C-States" is set to Enabled) Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to the operating system. During the CPU C3 State, the CPU clock generator is turned off.
  • Page 93 Chapter 7: BIOS LakeTiny Feature Select Enabled for LakeTing feature support. The options are Disabled and En- abled. ACPI T State Select Enabled for ACPI T state (processor throttling) feature support. The options are Disabled and Enabled. Chipset Confi guration WARNING: Setting the wrong values in the following sections may cause the system to malfunction.
  • Page 94 UPER ERVER 5018D-MF User's Manual This item allows the generation confi guration of PEG0 on the PCI-E slot. The options are Auto, Gen1, Gen2 and Gen3. PEG1 - Gen X This item allows the generation confi guration of PEG1 on the PCI-E slot. The options are Auto, Gen1, Gen2 and Gen3.
  • Page 95 Chapter 7: BIOS • CAS Latency (tCL) • Minimum Delay Time • CAS to RAS (tRCDmin) • Row Precharge (tRPmin) • Active to Precharege (tRASmin) Memory Frequency Limiter This feature sets the limit of memory frequency for DIMM modules installed on the the motherboard.
  • Page 96 UPER ERVER 5018D-MF User's Manual EHCI2 Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 2 for USB 2.0 support. One EHCI controller must always be enabled. The settings are Enabled and Disabled.. Legacy USB Support This feature enables support for legacy USB devices. Select Auto to disable legacy support if USB devices are not present.
  • Page 97 Chapter 7: BIOS  SATA Confi guration of the SATA Devices and displays the following items: SATA Controllers This item Enables or Disables the built-in SATA controllers on the motherboard. The options are Enabled and Disabled. SATA Mode Selection This item selects the mode for the installed SATA drives. The options are IDE, AHCI and RAID.
  • Page 98 UPER ERVER 5018D-MF User's Manual Serial ATA Port 0~ Port 5 This item displays the information detected on the installed SATA drives on the particular SATA port. • Model number of drive and capacity • Software Preserve Support If the item above - SATA Mode Select is set to RAID, the following items are...
  • Page 99 Chapter 7: BIOS VGA Palette Snoop Select Enabled to support VGA palette register snooping which will allow the PCI cards that do not contain their own VGA color palette to examine the video cards palette and mimic it for proper color display. The options are Disabled and Enabled.
  • Page 100: Acpi Settings

    UPER ERVER 5018D-MF User's Manual ment) to boot the computer using a PXE device installed in a LAN port specifi ed. Select Disabled to prevent system boot using a device installed in a LAN port. The options are Disabled, PXE and iSCSI. The default setting for Onboard LAN1 Op- tion ROM is PXE.
  • Page 101 Chapter 7: BIOS • SPS Version • ME FW (Firmware) Status Value • ME FW State • ME FW Operation State • ME FW Error Code • ME NM FW Status Value • BIOS Booting Mode • Cores Disabled • ME FW SKU Information •...
  • Page 102: Console Redirection Settings

    UPER ERVER 5018D-MF User's Manual SOL Change Settings This feature specifi es the base I/O port address and the Interrupt Request ad- dress of SOL Serial Port. Select Auto to let the BIOS automatically assign the base I/O and IRQ address. The options for Serial Port 2 are Auto, (IO=2F8h;...
  • Page 103 Chapter 7: BIOS Stop Bits A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2. Flow Control This feature allows the user to set the fl...
  • Page 104 UPER ERVER 5018D-MF User's Manual Console Redirection (for EMS) Select Enabled to use a COM Port selected by the user for Console Redirection. The options are Enabled and Disabled.  Console Redirection Settings (for EMS) This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
  • Page 105: Event Logs

    Chapter 7: BIOS Event Logs  Change SMBIOS Event Log Settings Enabling/Disabling Options SMBIOS Event Log Change this item to enable or disable all features of the SMBIOS Event Logging during system boot. The options are Enabled and Disabled. Erasing Settings Erase Event Log If No is selected, data stored in the event log will not be erased.
  • Page 106: View Smbios Event Log

    UPER ERVER 5018D-MF User's Manual SMBIOS Event Long Standard Settings Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled. The options are Disabled and Enabled. MECI The Multiple Event Count Increment (MECI) counter counts the number of oc- curences a duplicate event must happen before the MECI counter is incremented.
  • Page 107 Chapter 7: BIOS  IPMI The following IPMI information will be displayed: • IPMI Firmware Revision • IPMI Status  System Event Log This feature is used to change the Sytem Event Log (SEL) confi guration. SEL Components - Change this item to enable or disable all features of System Event Logging.
  • Page 108 UPER ERVER 5018D-MF User's Manual  BMC Network Confi guration LAN Channel 1: This feature allows the user to confi gure the settings for LAN1 Port. Update IPMI LAN Confi guration This feature allows the BIOS to implement any IP/MAC address changes at the next system boot.
  • Page 109: Boot Settings

    Chapter 7: BIOS Boot Settings Use this feature to confi gure Boot Settings: Set Boot Priority This option prioritizes the order of bootable devices that the system to boot from. Press [ENTER] on each entry from top to bottom to select devices. •...
  • Page 110 UPER ERVER 5018D-MF User's Manual  Delete Boot Option This feature allows the user to delete a previously defi ned boot device from which the systems boots during startup. The settings are [any pre defi ned boot device]  Delete Driver Option This feature allows the user to delete a previously defi...
  • Page 111: Security Settings

    Chapter 7: BIOS Security Settings This menu allows the user to confi gure the following security settings for the system. • If the Administrator password is defi ned ONLY - this controls access to the BIOS setup ONLY. • If the User's password is defi ned ONLY - this password will need to be entered upon each system boot, and will also have Administrator rights in the setup.
  • Page 112: Save & Exit

    UPER ERVER 5018D-MF User's Manual Save & Exit Select the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system confi...
  • Page 113 Chapter 7: BIOS Restore Optimized Defaults To set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are factory settings designed for maximum system stability, but not for maximum performance. Save As User Defaults To set this feature, select Save as User Defaults from the Exit menu and press <En- ter>.
  • Page 114 UPER ERVER 5018D-MF User's Manual Notes 7-32...
  • Page 115: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue with bootup.
  • Page 116 UPER ERVER 5018D-MF User's Manual Notes...
  • Page 117: Appendix B System Specifi Cations

    Appendix B: System Specifi cations Appendix B System Specifi cations Processors ® Single Intel Core™ i7/i5/i3 DT or Intel® Xeon® E3-1200 v3 or Intel® Xeon® E3-1200 v3 processor in an LGA1150 socket Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel C222 BIOS...
  • Page 118 UPER ERVER 5018D-MF User's Manual Weight Gross Weight: 18 lbs. (8.2 kg.) System Cooling Two 4-cm counter-rotating fans System Input Requirements AC Input Voltage: 100-240 VAC Rated Input Current: 6.3A (115V) to 3.24A (230V) Power Supply Rated Output Power: 350W (Model# PWS-351-1H) Rated Output Voltages: +3.3V (15A), +12...
  • Page 119 Appendix B: System Specifi cations Disclaimer (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in signifi...
  • Page 120 UPER ERVER 5018D-MF User's Manual Notes...

Table of Contents