Electrical Requirements; Grounding Instructions - GE GTUP270EM1WW Installation Instructions Manual

Unitized electric washer/dryer
Hide thumbs Also See for GTUP270EM1WW:

Advertisement

Available languages

Available languages

Installation
Instructions
Minimum
Clearance
Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
[]
PREPARING FOR INSTALLATION
OF NEW APPLIANCE
REMOVING LINT FROM WALL EXHAUST
OPENING
• Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
WALL
INTERNAL DUCT
CHECK THATEXHAUST
OPENING
DAMPER OPENS
AND CLOSES FREE L Y.
TILT THE APPLIANCE
SIDEWAYS AND REMOVE
THE FOAM SHIPPING PADS
BY PULLING ATTHE SIDES
AND BREAKING THEM
AWAY FROM THE APPLIANCE
LEGS. BE SURE TO REMOVE
ALL OF THE FOAM PIECES
AROUND THE LEGS.
After the machine is in the
home, remove remaining
packing material/carton
from washer.
DO NOT REMOVESHIPPING
ROD AT THIS TIME.
Removestyrofoam block.
Removethe bag containing
the Washer hoses and
parts parts from tub. Put
styrofoam block back in tub
opening to hold tub in place
during the rest of installation.
Move washer close to final
position. Make sure there
is at least a 28" clearance
on right side of washer to
remove shipping bar. PULL
SHIPPING BAROUTUSING
YELLOWPLASTIC HANDLE.
Keep bar so it can be
reinstalled if washer is ever
moved again.
H
Styrofoam Block
\
Washer hoses
and parts
I1
g
Yellow plastic handle
NEW HOME OR REMODELING FAUCETS/
DRAIN STANDPIPE/ELECTRICAL LOCATION
Right side of
Unitized Washer/
Dryer.
12"--_
Locate spigots,
"
drain standpipe
and electrical plug
in this area
I
FLOOR
Z-]ELECTRICAL CONNECTION
INFORMATION
- WARNING
- TOREDUCE
THE
RISK OF FIRE, ELECTRICAL
SHOCK AND
PERSONAL INJURY:
• DO NOT USE AN EXTENSION
CORD OR AN
ADAPTER
PLUG WITH THIS APPLIANCE.
Appliance must be electrically grounded in
accordance with local codes and ordinances, or in
the absence of local codes, in accordance with the
NATIONALELECTRICAL C ODE,ANSI/NFPANO. 70.
ELECTRICAL REQUIREMENTS
This appliance must be connected to an individual
branch circuit, protected by the required time-delay
fuses or circuit breakers. A four or three-wire, single
phase, 120/240V or 120/208V, 60Hz, :SO amp circuit
is required. If the electric supply does not meet the
above specifications, then call a licensed electrician.
GROUNDING
INSTRUCTIONS
A.For a grounded, cord-connected appliance:
This appliance must be grounded. In the event of mal-
function or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance
of electric current. This appliance is equipped with a
cord having an equipment-grounding
conductor and a
grounding plug. The plug must be plugged into an ap-
propriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
- ,WAR N IN
G
- Improper connection of the
equipment-grounding
conductor can result in a risk
of electric shock. Check with a qualified
electrician
or servicemen if you ere in doubt as to whether the
appliance is properly grounded.
4