Installation
Instructions
I-9-1MOBILEOR MANUFACTURED HOME
INSTALLATION
• Installation
MUST conform
to the MANUFACTURED
HOME CONSTRUCTION &, SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard
is not
applicable,
with AMERICAN NATIONAL STANDARD FOR
MOBILE HOME, ANSI/NFPA NO. 501B.
• The appliance
MUST be vented to the outdoors
with
the termination
securely fastened to the mobile home
structure.
• The vent MUST NOT be terminated
beneath a mobile or
manufactured
home.
• The vent duct material
MUST BE METAL.
• Do not use sheet metal screws or other fastening
devices which extend into the interior of the exhaust
vent.
• See section 2 for electrical
connection
information.
ALCOVE OR CLOSET INSTALLATION
ii
If your appliance is approved for installation in an
alcove or closet, it will be stated on a label on the
appliance
back.
• TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE
FROM ACCUMULATING AND TO MAINTAIN DRYING
EFFICIENCY, THIS MACHINE MUST BE EXHAUSTED
OUTDOORS.
• Do not install this appliance
with less than the minimum
clearances
shown above.
CONSIDERATION
MUST BE GIVEN TO PROVIDE
ADEQUATE CLEARANCES FOR INSTALLATION
AND SERVICE.
CAUTION: Do NOT INSTALL
THIS
APPLIANCE
IN A CLOSET WITH A SOLID DOOR.
DOOR VENTILATION OPENING (27"
MODELS)
A minimum of 120 square inches of opening, equally
divided at top and bottom, is required. Air openings are
required to be unobstructed when a door is installed.
A Iouvered door with equivalent air openings for the
full length of the door is acceptable.
27" Model
:
:1:, 16,o sq. in.
..........
H
H _0 Sq In
When louvers or registers are placed in door openings, the
free air openings
of the louvers or registers must equal 120
square inches.
DOOR VENTILATION
OPENING (24"
MODELS)
A minimum
of 72 square inches of opening
is required. Air
openings
are required
to be unobstructed
when a door is
installed. A Iouvered door with equivalent
air openings
for
the full length of the door is acceptable.
24" Model
Sq. In.
I1"
When louvers or registers are placed in door openings, the
free air openings
of the louvers or registers must equal 72
square inches.
Fi-_BATHROOH OR BEDROOM INSTALLATION
• The appliance
MUST be vented to the outdoors.
See
EXHAUST INFORMATION section 3 & 4.
• The installation
must conform
with local codes or, in the
absence
of local codes, with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.