5=
For 48" (121.9 cm) models only, rotate center support
counterclockwise
off the pallet until it stops.
11
6=
\
NOTE: This support is used only for shipping and is not
needed
for installation.
Lay a piece of cardboard from side packing on the floor
behind range. Using 2 or more people, firmly grasp each side
of range. Lift range up about 3" (8.0 cm) and move it back
until range is off shipping pallet. Set range on cardboard to
avoid damaging floor.
All ranges may require a backguard. See "Cabinet Dimensions" in
the "Location
Requirements" section. See the "Tools and Parts"
section for information
on ordering.
Remove island trim and attach backguard using 6 screws, insert
3 from the front and 3 from the back (9" [22.9 cm] backguard
shown).
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti=tip bracket to rear range foot.
Reconnect
the anti=tip bracket,
if the range is moved.
Failure to follow these instructions can result in death
or serious
burns to children
and adults.
1. Determine which mounting method to use: floor or wall.
2=
If you have a stone or masonry floor, you can use the wall
mounting method.
Determine and mark centerline of the cutout space. The
mounting bracket must be installed on the right side of the
cutout. Position mounting bracket in cutout as shown in the
following illustration.
Measurement
B:
30" (76.2 cm) ranges: 11%" (29.5 cm)
36" (91.4 cm) ranges: 14%" (37.1 cm)
48" (121.9 cm) ranges: 205/8 '' (52.4 cm)
Measurement
C:
Optional distance from backwall. If backwall is constructed
of a combustible
material and a backguard is not installed,
a 6" (15.2 cm) minimum clearance is required for all models.
Install anti-tip bracket accordingly.
C
A. Centerline
B. Centerline of cutout to centerline
of anti-tip bracket
C. Backwall to back of range
3. Drill two V8" (3.0 mm) holes that correspond
to the bracket
holes of the determined mounting method. See the following.
Floor Mounting
A
A. #12 x 1%" screws
B. Anti-tip bracket