Jenn-Air JDRP436WP01 Installation Instructions Manual page 6

30" (76.2 cm), 36" (91.4 cm), 48" (121.9 cm) commercial style dual fuel convection ranges
Table of Contents

Advertisement

Available languages

Available languages

48"(121.9 c m)models: 42"(106.7 c m) m inimum clearance
between thetopofthecooking p latform andthebottom ofan
uncovered wood ormetal cabinet.
***NOTE: Ifbackwall isconstructed ofacombustible material
anda backguard isnotinstalled, a 6"(15.2 cm)minimum
clearance isrequired forallmodels.
Ifcodes permit and aseparate ground w ire isused, i tis
recommended
thataqualified electrical installer determine that
theground p athand wire gauge areinaccordance withlocal
codes.
Ifcodes permit and aseparate ground w ire isused, i tis
recommended
thataqualified electrician determine that t he
ground p athisadequate.
Donotuse anextension cord.
Besure thattheelectrical connection andwire sizeareadequate
andinconformance
withtheNational Electrical Code, ANSI/
NFPA 7 0-latest edition a ndalllocal c odes a nd ordinances.
Acopyoftheabove c ode standards canbeobtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, MA 02269.
WARNING: Improper connection oftheequipment-grounding
conductor canresult inariskofelectric s hock. Check w itha
qualified electrician orservice t echnician ifyouareindoubt a sto
whether theappliance isproperly grounded. Donotmodify t he
power supply cordplug. I f itwillnotfittheoutlet, have a proper
outlet i nstalled bya qualified electrician.
Electrical
Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial
number rating plate is located under
the console on the right-hand side. Refer to the figures in the
"Product
Dimensions" section of the "Location
Requirements"
section.
This range may be manufactured with a 4-wire power supply
cord or may not include a power supply cord. If your range
does not include a power supply cord, use a 4-wire power
supply cord rated at 250 volts, 40 or 50 amps and
investigated for use with ranges.
Range Rating*
Specified Rating of Power
Supply Cord Kit and
Circuit Protection
120/240 Volts
120/208 Volts
Amps
Range Size
8.8 - 16.5 kW
7.8 - 12.5 kW
40 or 50"*
30" (76.2 cm),
36" (91.4 cm)
16.6 - 22.5 kW
12.6 - 18.5 kW
50
48" (121.9 cm)
*The NEC calculated load is less than the total connected
load
listed on the model/serial
rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 13/8"(34.9 mm) diameter connection opening.
A circuit breaker is recommended.
Wire sizes and connections must conform with the rating of
the range.
The Tech Sheet is located behind the kick plate in a clear
plastic bag.
If connecting
to a 4-wire
system:
This range is manufactured
with the ground connected to the
cabinet. The ground must be revised so the green ground wire of
the 4-wire power supply cord is connected to the cabinet. See
"Electrical Connection."
Grounding through the neutral conductor
is prohibited for new
branch-circuit
installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power
supply cord must be used. This cord contains 4 copper
conductors
with ring terminals or open-end spade terminals with
upturned ends, terminating
in a NEMA Type 14-50R plug on the
supply end.
The fourth (grounding) conductor
must be identified by a green or
green/yellow cover and the neutral conductor
by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
4-wire receptacle
(14-50R)
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting
to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt,
40- or 50-amp range power supply cord (pigtail). This cord
contains 3 copper conductors
with ring terminals or open-end
spade terminals with upturned ends, terminating
in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire
receptacle
(10-50R)
6