Editing A Patch; Checking The Current Value Of A Parameter (Temporary Scope) - Roland JP-8080 Owner's Manual

Synthesizer module
Hide thumbs Also See for JP-8080:
Table of Contents

Advertisement

Editing a Patch

You can move the sliders and knobs etc. of the front panel
to modify the sound of the selected Patch.
1
Use PANEL SELECT [LOWER]/[UPPER] to select
the Part whose Patch you wish to edit.
If you press both [LOWER] and [UPPER] simultaneous-
ly, both indicators will light, and you can simultaneous-
ly edit the Patches of both Parts.
In this case, the panel will show the settings of the
Upper Patch.
2
Use the panel sliders and knobs etc. to edit the
Patch.
*
When the [UPPER] and [LOWER] indicators are blink-
ing, moving the panel sliders/knobs displayed in blue
will edit the Voice Modulator parameters. (p.111)
Checking the Current Value of a
Parameter (Temporary Scope)
When you wish to check the current value of a parameter
(the parameter value in the temporary area), use the follow-
ing procedure to view the value.
*
While Temporary Scope page is displayed, the parame-
ters will not edit if you move the sliders/knobs.
*
The values of the following knobs cannot be viewed in
the display.
• VOLUME [LEVEL]
• EXTERNAL INPUT [INST/LOWER] and [VOCAL/UPPER]
1
Press [EDIT].
The [EDIT] indicator will light and the BANK [1]–[8]
indicators will blink.
2
Press [SCOPE] (BANK [8]) to access the Temporary
Scope display.
The [SCOPE] indicator will light.
3
Move the slider/knob of the parameter whose value
you wish to check.
The parameter name and temporary value of the slid-
er/knob you moved will appear in the display.
By pressing [DEC]/[INC] you can modify the value in
steps of 1.
*
If at this time you press [SCOPE], the lower left of the
display will indicate (Edit), and you will enter Edit
Scope mode (see following section).
4
To end Temporary Scope, press [EDIT] or [EXIT].
*
If you use the Temporary Scope when the Voice
Modulator panel (p.111) is selected, an "x" will some-
times appear in the display. This indicates that when the
algorithm (p.108) is set to "FLT BANK WIDE" or "FLT
BANK NARROW," this parameter is invalid.
Velocity Scope and Control Scope
The width of change for the various parameters assigned to
Velocity (p.82) or Control (p.84) can be verified in the dis-
play.
1
When the Temporary Scope page is displayed,
press [VELOCITY ASSIGN] or [CONTROL
ASSIGN].
The indicator will blink, and the display will indicate
either "Velocity Scope" or "Control Scope."
2
Move the slider/knob whose value you wish to veri-
fy.
The parameter and width of change for the slider/knob
you moved will be displayed.
You can use [DEC]/[INC] to modify the value in steps
of one.
*
If at this point you press [SCOPE] (BANK [8]), the dis-
play will indicate (E), and you will enter the correspond-
ing Edit Scope (refer to the following section).
3
When you press [VELOCITY ASSIGN], [CON-
TROL ASSIGN] or [EXIT], you will return to the
Temporary Scope page.