Denso QK20-R User Manual page 81

2d code scanner (fixed type)
Table of Contents

Advertisement

Items
Transmission of Start/Stop codes
for Codabar (NW-7)
Check digit method for Codabar (NW-7)
Code 39
Items
Reading Code 39
Minimum number of readable digits for
Code 39
Maximum number of readable digits for
Code 39
Transmission of Start/Stop codes
for Code 39
Conversion to FULL ASCII
Code 128, GS1-128 (EAN-128)
Items
Reading Code 128
Reading GS1-128 (EAN-128)
Minimum number of readable digits for
Code 128
Maximum number of readable digits for
Code 128
Transmission of FNC1 for
Code 128
Minimum number of readable digits for
GS1-128 (EAN-128)
Maximum number of readable digits for
GS1-128 (EAN-128)
Transmission of FNC1 for GS1-128
(EAN-128)
(Note 1) The setting ranges are different from the numbers of digits that the scanner can actually read.
(Note 2) Using the QR-coded parameter menu enables or disables scanning of both Code 128 and GS1-128 (EAN-128) at
the same time.
Parameters
Transmit a/b/c/d
Transmit A/B/C/D
Disable
MOD-16
7-check method
Parameters
Enable, without a check digit
Enable, with a check digit
(Check digit transmission enabled)
Enable, with a check digit
(Check digit transmission disabled)
Disable
1 to 99 digits
(excluding start/stop codes)
Enable
Disable
Enable
Disable
Parameters
Enable
Disable
Enable
Disable
1 to 99 digits
(excluding start/stop codes and
1-digit check digit)
Disable
Transmit GS
1 to 99 digits
(excluding start/stop codes and
1-digit check digit)
Disable
Transmit GS
70
Defaults
Defaults
1 digit
99 digits
Defaults
1 digit
99 digits
1 digit
99 digits
: Can be changed only with the configuration software.
Refer to:
Section 11.3
Refer to:
Section 11.3
(See Note 1.)
Section 11.3
Refer to:
Section 11.3
(See Note 2.)
(See Note 1.)
Section 11.3
(See Note 1.)