D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Mantels
5
4
3
11-3/4
11
10-1/4
6
Figure 5.3
Minimum Vertical and Maximum Horizontal Dimensions
Mantel Legs or Wall Projections
Top of
Appliance
A
1 in. (25 mm) min.
to perpendicular wall
B
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
Figure 5.4
Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
13
12
11
10
17
9
8
16-1/4
7
15-1/2
6
14-3/4
14
13-1/4
12-1/2
Measured from top of hood (in inches)