D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Combustible Mantels
1/2 IN.
Thick Wall
Sheathing
14 IN.
MIN.
Figure 5.3 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Non-combustible Mantels
1/2 IN.
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
See Dimension T on
Appliance Dimension
Diagram (Figure 16.1).
Figure 5.4 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
Note: For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 13.C.
20
12 IN.
MAX.
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
See Dimension T on Appliance
Dimension Diagram (Figure 16.1).
12 IN.
MAX.
14 IN.
MIN.
1 IN.MIN.
4 IN.
MAX.
Heatilator • RAVE4013I-D • 2328-900 Rev. F • 9/17
Mantel Legs Or Wall Projections Extending Past The Face
Of The Fireplace (Combustible or Non-Combustible)
6 IN.
MINIMUM
3 FT. MAXIMUM
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 16.1).
Figure 5.5 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
7 IN.
MINIMUM
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 16.1).
Figure 5.6 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Figure 5.7 Front Side Finishing Detail
Note: Clearance from opening
to perpendicular wall.
Note: Clearance from opening
to perpendicular wall.
UNLIMITED
1 IN.
FRAMING
NAILING TAB
1/2 IN. FACTORY-SUPPLIED
NON-COMBUSTIBLE BOARD