Finishing; Facing Material; Combustible Mantel And Wall Projections - Heatilator NDV30-IFT Installation Manual

Table of Contents

Advertisement

10
10

Finishing

A. Facing Material
WARNING
Risk of Fire!
DO NOT apply combustible materials beyond the min-
imum clearances. Comply with all minimum clearanc-
es to combustibles as specified in this manual. Ma-
terials overlapping into non-combustible zones could
ignite and will interfere with air flow through decorative
barrier fronts.
• Metal front of appliance may be covered with non-
combustible materials only.
• Facing and/or finishing materials must not interfere
with air flow through decorative barrier fronts, removal
of decorative barrier fronts or access for service.
• Facing and/or finishing materials must never
overhang into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal gaps between the finished wall and appliance
top and sides using a 300 ºF minimum sealant.
NOTICE: Surface temperatures around the appliance will
become warm while the appliance is in operation. Ensure
finishing materials used for all surfaces (floor, walls,
mantels, etc.) will withstand temperatures up to 190 °F.
Heatilator • NDV30-IFT, NDV33-IFT, NDV36-IFT, NDV36-IFT-NVR, NDV42-IFT Installation Manual • 2620-980 Rev. C • 8/20
B. Combustible Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specified. Framing closer than the minimums list-
ed must be constructed entirely of non-combustible materi-
als (i.e., steel studs, concrete board, etc.).
Note: Mantel Measurement is taken from top of the
opening, NOT the top of the fireplace.
Combustible Mantels
Note: All
measurements
in inches.
8
7
6
8-1/2
5
7-3/4
4
7
3
6-1/4
5-1/2
5
Measured from top of hood or appliance opening (in inches).
Refer to Section 3.B for additional clearances to combustibles information.
Figure 10.1
Minimum Vertical and Maximum Horizontal
Dimensions for Combustible Mantels
Combustible Mantel Legs or Wall Projections
TOP OF
APPLIANCE
1 in. (max)
FIREPLACE
OPENING
See Dimension B on
Appliance Dimension
Diagram.
Figure 10.2
Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
30 in. minimum
to ceiling
17
16
15
15-1/4
14
14-1/2
13
13-3/4
12
13
11
12-1/4
10
11-1/2
9
10-3/4
10
9-1/4
STOP FINISHING MATERIAL
FLUSH WITH OUTSIDE EDGE
OF APPLIANCE.
DRYWALL
1 in.
UNLIMITED
(min)
MANTEL LEG OR
PERPENDICULAR WALL
18
16
51