D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Mantels
8
7
6
8-1/2
5
7-3/4
4
7
3
6-1/4
5-1/2
5
Measured from top of hood (in inches)
Figure 5.3
Clearances To Mantels Or Other Combustibles Above
Appliance
All manuals and user guides at all-guides.com
30 in. minimum
to ceiling
18
17
16
15
15-1/4
14
14-1/2
13
13-3/4
12
13
11
12-1/4
10
11-1/2
9
10-3/4
10
9-1/4
Heatilator • Novus NDV Series • 4055-187 Rev. AA • 10/13
Mantel Legs or Wall Projections
Top of
Appliance
16
Figure 5.4
sides of opening)
A
B
Mantel Leg or
Perpendicular Wall
A
1 in. (25 mm) min.
to perpendicular wall
B
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
Mantel Leg or Wall Projections (Acceptable on both