Heatilator CRAVE4836-B Installation And Appliance Setup
Heatilator CRAVE4836-B Installation And Appliance Setup

Heatilator CRAVE4836-B Installation And Appliance Setup

Hide thumbs Also See for CRAVE4836-B:
Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator CRAVE4836-B

  • Page 1 See Table of Contents for location of additional Commonwealth gases, unless a certified kit is used. of Massachusetts requirements. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 2: Table Of Contents

    C. Securing and Leveling the Appliance ....35 D. Installing Non-Combustible Facing Material ..36  = Contains updated information. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2301-975 Rev. B 4/17 Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 4: Product Specific And Important Safety Information

    5 mm ceramic glass. Please contact CRAVE8472ST-B (0-2000 FT) 58,000 30,000 your dealer for replacement glass. (NG) CRAVE8472ST-B 46,000 24,000 (0-2000 FT) (Propane) Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 5: High Altitude Installations

    • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 7: Getting Started

    30 degrees or more depending on the thermometer settings and material characteristics being measured. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 8: Tools And Supplies Needed

    Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 9: Framing And Clearances

    24-1/2 1600 1600 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 46-3/16 1173 1473 23-3/4 23-3/4 17-1/8 17-1/8 30-1/2 30-1/2 Figure 3.1 Appliance Dimensions - CRAVE4836-B,CRAVE6048-B Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 10 24-1/2 7-1/4 7-1/4 1600 1905 8-7/8 8-7/8 8-9/16 8-9/16 2-3/4 2-3/4 23-3/4 23-3/4 1778 2083 17-1/8 17-1/8 30-1/2 30-1/2 Figure 3.2 Appliance Dimensions - CRAVE7260-B, CRAVE8472-B Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 11 1600 1600 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 46-3/16 1173 1473 23-3/4 23-3/4 17-1/8 17-1/8 30-1/2 30-1/2 Figure 3.3 Appliance Dimensions - CRAVE4836ST-B, CRAVE6048ST-B Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 12 24-1/2 1600 1905 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 1778 2083 23-3/4 23-3/4 17-1/8 17-1/8 30-1/2 30-1/2 Figure 3.4 Appliance Dimensions - CRAVE7260ST-B, CRAVE8472ST-B Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 13 The Four Square decorative front has an installed depth of 2-1/8 in. (54 mm), measured from the front of the non-combustible finishing material to the front of the decorative front. Figure 3.5 Four Square (Overlap Fit) Decorative Front Dimensions Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 14 The Illusion decorative front has an installed depth of 2-1/2 in. (64 mm), measured from the front of the non-combustible finishing material to the front of the decorative front. Figure 3.6 Illusion (Overlap Fit) Decorative Front Dimensions Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 15 37-3/16 49-3/16 1249 61-3/16 1554 73-3/16 1859 40-5/16 1024 52-5/16 1329 64-5/16 1634 76-5/16 1938 Figure 3.7 Clean Face Trim Front (Inside Fit) Decorative Front Dimensions Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 16: Clearances To Combustibles

    18-3/4 10.14 and CRAVE7260-B Millimeters 2019 1835 2854 10.15. Inches 84-1/4 124-3/8 35-1/4 18-3/4 CRAVE8472-B Millimeters 2235 2140 3159 Figure 3.8 Appliance Locations: CRAVE Single-Sided Models Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 17 17-1/8 CRAVE6048ST-B Millimeters 1530 1219 Inches 72-1/4 17-1/8 CRAVE7260ST-B Millimeters 1835 1219 Inches 84-1/4 17-1/8 CRAVE8472ST-B Millimeters 2140 1219 Figure 3.9 Appliance Locations: CRAVE See-Through Models Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 18 ***= If appliance is installed off of floor, maintain required clearances to combustibles. Construct platform in accordance with local building codes. Figure 3.10 Clearances to Combustibles-CRAVE4836-B, CRAVE6048-B, CRAVE7260-B, CRAVE8472-B Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 19 ***= If appliance is installed off of floor, maintain required clearances to combustibles. Construct platform in accordance with local building codes. Figure 3.11 Clearances to Combustibles-CRAVE4836ST-B, CRAVE6048ST-B, CRAVE7260ST-B, CRAVE8472ST-B Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 20: Constructing The Appliance Chase

    However, this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained. Figure 3.12 Floor Protection Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 21: Termination Location And Vent Information

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 22: Chimney Diagram

    2 sides beneath the floor. • Vinyl siding shield is required for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination See Service Parts list for information. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 23: Approved Pipe

    • Horizontal termination cap should have a 1/4 inch downward slant to allow any moisture in cap to be released. Vertical 8-1/2 in. Horizontal Figure 4.4 Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 24 18 ft. 5.5 m 9 ft. 2.7 m 21 ft 6.4 m = 63 ft. (19.2 m) Maximum = 40 ft. (12.2 m) Maximum Figure 4.5 Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 25 = 63 ft. (19.2 m) Maximum = 63 ft. (19.2 m) Maximum = 40 ft. (12.2 m) Maximum = 40 ft. (12.2 m) Maximum INSTALLED HORIZONTALLY Figure 4.6 Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 26 = 63 ft. (19.2 m) Maximum = 40 ft. (12.2 m) Maximum = 63 ft. (19.2 m) Maximum = 40 ft. (12.2 m) Maximum Figure 4.7 Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 27 Note: If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed. Note: Use DVP Series components only. Figure 4.8 Vertical Vent Maximum Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 28 NOTICE: Before painting, contact your dealer for information on the appropriate high temperature paint. Figure 4.11 Set the Exhaust Restrictor Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 29 15 ft. 4.5 m = 23 ft. (7.1 m) Maximum Total = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Total Figure 4.12 Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 30 15 ft. 4.5 m = 23 ft. (7.1 m) Maximum = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum INSTALLED HORIZONTALLY Figure 4.13 Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 31: Vent Clearances And Framing

    (1) in. (25.4 mm) above the center of the horizontal vent pipe. Note: Measurements were taken with a 2 ft. vertical section of pipe directly off the top of appliance. Figure 5.2 Wall Penetration Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 32: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 33: Installing The Optional Heat-Zone ® Gas Kit

    • Determine the location for the air register/fan housing assembly. Reference the Heat-Zone or Heat-Duct instructions for ® the remaining installation steps. Figure 5.5 Heat Zone Adapter Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 34: Appliance Preparation

    Figure 6.3 Location of Fiberglass Rope Ring HEAT SHIELD GASKET ROPE RING Heat Shield Shipping Position Heat Shield Installation Position Figure 6.2 Heat Shield Shown Installed Figure 6.4 Fiberglass Rope Ring Installed Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 35: Securing And Leveling The Appliance

    SHIPPING SHIPPING FLANGE FLANGE Figure 6.7 Nailing Tabs Figure 6.6 Nailing Tabs Installation Position Shipping Position NAILING TABS BOTH SIDES Figure 6.5 Nailing Tab Locations Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 36: Installing Non-Combustible Facing Material

    • Use a wet or dry towel or soft brush to remove dust or dirt from facing material. • See Section 10 for finishing materials guidelines. Figure 6.8 Install Factory-Included Non-Combustible Facing Material Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 37: Venting And Chimneys

    Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate Figure 7.4 Seams inner pipe. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 38: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 39: Disassemble Vent Sections

    Figure 7.10 • Pull carefully to separate the pieces of pipe. Figure 7.9 Rotate Seams for Disassembly Figure 7.10 Align and Disassemble Vent Sections Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 40: Vertical Termination Requirements

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 41: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be field constructed. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 42 1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 7.15 Venting Through the Wall Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 43: Electrical Information

    3. Remove screws on left and right sides of component SUPPLY heat shield and lift it out of the control cavity. Figure 8.3. Valve Cavity (Lower Access Panel Removed) Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 44: Wiring Requirements

    CORD ADAPTER BLACK BROWN OPTIONAL ORANGE GREEN (PILOT) (MAIN) GROUND LED CONTROL BATTERY PACK 6V DC LED LIGHT TRAY Figure 8.4 IntelliFire™ Plus Wiring Diagram with Remote Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 45: Gas Information

    3. Unplug the 6V transformer from the junction box. pressure testing gas line at test pressures equal to or less than 1/2 psig. This will turn the power off to the appliance. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 46 Figure 9.5. Gas Fitting Access with Bottom Glass Shield Removed BURNER ASSEMBLY 4836 & 6048 BURNER ASSEMBLY 7260 & 8472 Figure 9.3. Media Tray with Burner and Pilot Shield Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 47: Gas Connection

    Fittings and connections could have loos- ened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 48: Air Shutter Setting

    Appliance-Standard 1/2 in. Full Open With Glass Refractory 1/2 in. Full Open Installed With Log Kit Installed 1/2 in. Full Open Figure 9.6 Air Shutter Location Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 49: Finishing

    Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC. WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Inadequate air space could cause overheating and fire. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 50 WARNING! Risk of Fire! DO NOT install drywall or other combustible materials directly onto the installed non-combustible board. Overlapping materials could ignite. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 51 Included & Used (Option #2) Clean Face Trim (CFT) Overlap Fit 0-1 inch Included & Used Four Square/Illusion Overlap Fit 0-1 inch Not included Table 1. Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 52 INSIDE FIT = 1-4 IN. THICK INSIDE FIT = 1-4 IN. THICK FINISHING FINISHING GUARDS GUARDS BOTTOM FINISHING TEMPLATE BOTTOM FINISHING TEMPLATE Figure 10.3 Finishing Materials - See-Through Models Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 53: Decorative Fronts

    Included & Used 39-1/8 IN.CRAVE4836-B/CRAVE4836ST-B 51-1/8 IN.CRAVE6048-B/CRAVE6048ST-B 63-1/8 IN.CRAVE7260-B/CRAVE7260ST-B 75-1/8 IN.CRAVE8472-B/CRAVE8472ST-B 15-3/4 IN. FIREPLACE VIEWING AREA Figure 10.4 Minimum Finished Opening Dimensions - Clean Face Trim Front Method Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 54 SHOULDER BOLTS (4) • Over-heating and fire could occur. BOTTOM PANEL BOTTOM GLASS SHIELD RECTANGULAR HOLE Figure 10.6. Install Shoulder Bolts Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 55 12 IN. MAX Inch Thick Inside Fit Method Using Trim Ring (Option #2) Figure 10.8 Finishing and Facing Materials - Inside Fit CFT Decorative Front Only Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 56 BOTTOM FINISHING TEMPLATE BOTTOM PANEL = RECTANGULAR ACCESS HOLES DO NOT COVER Figure 10.9 Non-Combustible Finish Material Diagram for 0-1 Inch Thick Overlap Fit Method (Four Square/Illusion) Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 57 51-1/8 IN.CRAVE6048-B/CRAVE6048ST-B 63-1/8 IN.CRAVE7260-B/CRAVE7260ST-B 17-1/4 IN. FIREPLACE VIEWING AREA Figure 10.10 Minimum Finished Opening Dimensions - Overlap Fit Method (Four Square and Illusion Decorative Fronts Only) Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 58: Mantel And Wall Projections

    Measurement from top edge opening to bottom of appliance = 24-1/2 IN. Figure 10.12 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles - CRAVE4836-B and CRAVE6048-B Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 59 Figure 10.16 Mantel Leg or Wall Projections Figure 10.17 Mantel Leg or Wall Projections (Acceptable on both sides of opening) (Acceptable on both sides of opening) Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 60: Appliance Setup

    An optional log set is available for use with the CRAVE models. Install the log set per instructions included with kit. Figure 11.1 Fixed Glass Assembly Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 61: Reference Materials

    (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 12.1 DVP Vent Components Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 62 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 12.2 DVP Vent Components Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 63 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 12.3 DVP Vent Components Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 64 213 mm 146 to 213 mm 3° 87° 15 in. (381 mm) 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-SS DVP-HRC-ZC-SS Figure 12.4 DVP Vent Components Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 65 Adapter Adapter 7-3/8 IN. 187 mm 17-7/8 IN. 454 mm 14 IN. 356 mm 12 IN. 305 mm SLP-TB1 Basement Vent Cap Figure 12.5 Vent Components Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 66 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS Heat Shield PVLP-BEK Brick Kit Figure 12.6 PVLP-SLP Vent Components Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...
  • Page 67: Accessories

    Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer, please visit www.heatilator.com. Printed in U.S.A. - Copyright 2017 Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17...

Table of Contents