J. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
optional remote. The unit should be in the OFF position
during installation, service, fuel conversion, and in the
event that the control goes into LOCK-OUT mode as a
result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI fl ame setting, with no adjustment in fl ame
output. This mode of operation is primarily used for
initial installation and inspection.
REMOTE Position: Appliance will initiate commands
from a wired wall switch and/or one of the optional
wireless remote options.
2. A wall switch can be wired into the control module brown
and red wires. See Figure 12.1.
3. The control module has safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the wall
switch or optional remote.
4. If you intend to use both a wired wall switch and an
optional remote control to operate your fi replace, the
wall switch will override any commands given by the
remote.
GRAY MODULE
HI/LOW FLAME
ADJUSTMENT
WIRE LEAD FROM REGULATOR CONNECTS HERE
Figure 2.3 Control Module
Note: The HI/LO and LP/NG switches on the control module
are non-functional on the XLR fi replace.
12
SELECTOR
SWITCH
NG/LP SETTING
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. D • 6/11
5. Module Reset Switch
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into
lock-out mode by emitting three audible beeps, then
continuously displaying a RED/GREEN error code at
its status indicator LED.
Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section H.
Locate the module reset switch. See Figure 2.4 or 2.5.
Set the module reset switch to the RESET position.
• Wait fi ve (5) minutes to allow possible accumulated gas
to clear.
Set the module reset switch to ON.
Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time within a fi ve minute
time period. Gas may accumulate in fi rebox. Call a quali-
fi ed service technician.
MODULE RESET
SWITCH
Figure 2.4 Location of Module Reset Switch - Tonic Front
MODULE RESET
SWITCH
Figure 2.5 Location of Module Reset Switch - Martini Front