2.3 CONTROL MODULE OPERATION

1.
The control module has an ON/OFF/REMOTE
selector switch that must be set. See Figure 43.
OFF Position: Appliance will ignore all power
inputs and will not respond to any commands
from a wall switch or optional remote. The unit
should be in the OFF position during installation,
service, battery installation, fuel conversion, and
in the event that the control goes into LOCK-
OUT mode as a result of an error code.
ON Position: Appliance will ignite and run
continuously in the HI fl ame setting, with no
adjustment in flame output. This mode of
operation is primarily used for initial installation
or power outage operation with battery backup.
REMOTE Position: Appliance will initiate
commands from a wired wall switch and/or one
of the optional wireless remote options.
2.
A wall switch can be wired into the control module
brown and red wires. See Figure 44.
3.
If using a wired wall switch with the module in
REMOTE mode, the fl ame output can be adjusted
with the HI/LO selector switch on the module.
See Figure 45. Note that the fl ame HI/LO selector
switch will become inactive once an optional
remote control (RC200/RC300) is programmed to
the control module. Note that the control module
will always ignite the fi replace on HI and remain
so for the initial 10 seconds of operation. If the HI/
LO is switched to the LO position, the fl ame output
will automatically drop to the lowest setting after
the fl ame has been established for 10 sec. After
this 10 second period, the fl ame can be adjusted
from HI to LO with the switch.
4.
The control module has safety feature that
automatically shuts down the fi replace after 9
hours of continuous operation without receiving
a command from the wall switch or optional
remote.
5.
If you intend to use both a wired wall switch and an
optional remote control to operate your fi replace,
the wall switch will override any commands given
by the remote.
6.
The module has the capability to recognize
potential malfunctions. If these occur, it will fail
to ignite and/or respond to a command to ignite
via the wall switch and/or optional remote. In this
case, the module may have gone into LOCK-OUT
mode. In this state, it will emit a LED error code.
To reset the error code, switch the selector to OFF,
and then back to REMOTE or ON. If the ignition
command again fails, the module will emit an
LED error code, prior to going back into LOCK-
OUT mode. Contact your dealer for service if this
occurs.
33
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15
MODULE
FLAME HI/LOW
STATUS
SWITCH
INDICATOR LED
Figure 45. Control Module
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that auto-
matically shuts down the fi replace after 9 hours of
continuous operation without receiving a command
from the RC300AU remote.