26. DOMESTIC WATER HEATING BUTTON
This button enables or disables heating of the domestic water.
This button is not used when the domestic hot water tank is not
installed.
INFORMATION
Remark that pushing the
on the domestic water heating. Domestic water
heating is only switched on or off by means of the
v
button.
27. WEATHER DEPENDENT SET POINT BUTTON
This button enables or disables the weather dependent set point
function which is available in space heating/cooling operation.
If the controller is set in permission level 2 or 3 (refer to
settings" on page
13), the weather dependent set point button
will not be operable.
28. INSPECTION/TEST OPERATION BUTTON
This button is used for installation purposes and changing field
settings. Refer to
"5. Field settings" on page
29. PROGRAMMING BUTTON
This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.
30. SCHEDULE TIMER BUTTON
The main function of this multi-purpose button is to enable/
disable the schedule timer.
The button is also used to program the controller. The function of
the button depends on the actual status of the controller or on
previous actions carried out by the operator.
If the controller is set in permission level 3 (refer to
settings" on page
13), the schedule timer button will not be
operable.
31. TIME ADJUST BUTTON
These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (refer to
temperatures" on page
8) and in schedule timer programming
mode.
32. TEMPERATURE ADJUST BUTTONS
These multi-purpose buttons are used to adjust the current set
point in normal operation mode or in schedule timer
programming mode. In weather dependent set point mode the
buttons are used to adjust the shift value. Finally, the buttons are
also used to select the weekday while setting the clock.
33. DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS
wbi
and
wbj
These buttons are used to adjust the current set point of the
domestic hot water temperature (only for [4-03]=0, 1, 2, or 3).
These buttons are used to adjust the current storage set point of
the domestic hot water temperature (only for [4-03]=4 or 5).
The buttons are not used when the domestic hot water tank is
not installed.
NOTICE
The setting [4-03] shall not be modified. The installer
selected the proper setting for your application.
INFORMATION
The status of this setting is only mentioned to indicate
which settings and functions are applicable for your
application.
[4-03]=0, 1, 2, 3, or 4 is only for domestic hot water
tank with built-in electrical booster heater (EKHW*).
[4-03]=5 is only for domestic hot water tank without
electrical booster heater (EKHTS).
Operation manual
5
v
y
button has no influence
ba
z
13.
<
r
/
p
pi
and
pj
"Displaying actual
bi
and
bj
34. QUIET MODE BUTTON
This button enables or disables quiet mode.
If the controller is set in permission level 2 or 3 (refer to
settings" on page
operable.
35. BIVALENT FUNCTION OR EXTERNAL BACKUP HEATER
ACTIVE R
This icon indicates that the bivalent function or external backup
heater permission signal is active.

4.4. Setting up the controller

After initial installation, the user can set the clock and day of the
week.
"5. Field
The controller is equipped with a schedule timer that enables the user
to schedule operations. Setting the clock and day of the week is
required to be able to use the schedule timer.

Setting the clock

1
Hold down the
The clock read-out and the day of week indicator start flashing.
2
Use the
pi
Each time the
increase/decrease by 1 minute. Keeping the
button pressed will increase/decrease the time by 10 minutes.
3
Use the
bi
Each time the
"5. Field
previous day is displayed.
4
Press the
week.
To leave this procedure without saving, press the pr button.
If no button is pressed for 5 minutes the clock and day of the
week will return to their previous setting.
INFORMATION
The clock needs to be set manually. Adjust the setting
when switching from summertime to wintertime and vice
versa.

Setting the schedule timer

To set the schedule timer, refer to chapter
consulting the schedule timer" on page
s
13), the quiet mode button will not be
pr
button for 5 seconds.
and
pj
buttons to adjust the clock.
pi
or
pj
button is pressed, the time will
or
bj
button to adjust the day of the week.
bi
or
bj
button is pressed the next or
<
button to confirm the current set time and day of the
9.
Unit and options for air to water heat pump system
"5. Field
pi
or
pj
"4.7. Programming and