Summary of Contents for Daikin Altherma 3 M Series

  • Page 1 Operation manual Daikin Altherma 3 M EBLA09~16DAV3 EBLA09~16DAW1 EBLA09~16DA3V3 EBLA09~16DA3W1 EDLA09~16DAV3 EDLA09~16DAW1 Operation manual EDLA09~16DA3V3 English Daikin Altherma 3 M EDLA09~16DA3W1...
  • Page 2: Table Of Contents

    7 Maintenance and service Latest revisions of the supplied documentation may be available on Overview: Maintenance and service ......... 18 the regional Daikin website or via your installer. 8 Troubleshooting The original documentation is written in English. All other languages To display the help text in case of a malfunction.......
  • Page 3: User Safety Instructions

    Cleaning and user maintenance MUST well-ventilated room without NOT be carried out by children without continuously operating ignition sources supervision. (example: open flames, an operating gas appliance or an operating electric heater). EBLA09~16DA + EDLA09~16DA Operation manual Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 4: About The System

    User pin code ▪ Heat up a space The User pin code is 0000. ▪ Cool down a space ▪ Produce domestic hot water (if a DHW tank is installed) Operation manual EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 5: Space Heating/Cooling

    Additional zone – Heating [3.5] Additional zone > Heating WD curve Room Additional zone – Cooling [3.6] Additional zone > Cooling WD curve 2 Change the weather-dependent curve. EBLA09~16DA + EDLA09~16DA Operation manual Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 6: Domestic Hot Water

    ([C.3]: Operation > Tank), disinfection mode will remain active. However, if you turn it OFF while disinfection is running, an AH error occurs. Slot for WLAN cartridge USB connector Operation manual EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 7 Slot for WLAN cartridge With the WLAN cartridge, the installer can connect the system to the internet. As user you can then control the system via the Daikin Residential Controller app. Note: This slot cannot be used for SD cards.
  • Page 8: Menu Structure: Overview User Settings

    Only applicable for reversible models (**) Only accessible by installer (***) Only applicable when WLAN is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. Operation manual EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 9: Possible Screens: Overview

    Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs. Item Description a Domestic hot water Domestic hot water Measured tank temperature EBLA09~16DA + EDLA09~16DA Operation manual Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 10: Main Menu Screen

    LAN (WLAN) is installed. gateway 5.3.2 Main menu screen Contains settings needed when configuring the Daikin Residential Starting from the home screen, press ( ) or turn ( ) the Controller app. left dial to open the main menu screen. From the main menu, you can access the different setpoint screens and submenus.
  • Page 11: Detailed Screen With Values

    Room temperature control OFF 1 Go to [C.2]: Operation > Space heating/cooling. Operation Room Space heating/cooling Tank 2 Set operation to On or Off. EBLA09~16DA + EDLA09~16DA Operation manual Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 12: Reading Out Information

    2 Select No. Check which space operation mode is Home screen currently used. Set the space operation mode permanently. Main menu Restrict automatic changeover according to a monthly schedule. Operation manual EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 13: To Change The Desired Leaving Water Temperature

    Example: 60°C 50°C 60°C 40°C 50°C 45°C 35°C 15°C 15°C 00:00 07:00 14:00 21:00 00:00 07:00 14:00 21:00 DHW tank temperature Time Domestic hot water tank temperature EBLA09~16DA + EDLA09~16DA Operation manual Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 14: Using Dhw Powerful Operation

    6 Give the schedule a name. To go to the schedule 1 Go to [1.1]: Room > Schedule. 2 Set scheduling to Yes. 3 Go to [1.2]: Room > Heating schedule. Operation manual EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 15 4 To name the current schedule, browse through the character list and confirm the selected character. The schedule name can contain up to 15 characters. 5 Confirm the new name. INFORMATION Not all schedules can be renamed. EBLA09~16DA + EDLA09~16DA Operation manual Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 16: Weather-Dependent Curve

    "5.9.4 Using weather-dependent 5.9.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) Example Weather-dependent curve when offset is selected: Operation manual EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 17: Using Weather-Dependent Curves

    The following table describes how to fine-tune the weather- [2.4] Main zone > Setpoint Weather dependent dependent curve of a zone or tank: mode Additional zone – Heating EBLA09~16DA + EDLA09~16DA Operation manual Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 18: Energy Saving Tips

    1 Go to [8.3]: Information > Dealer information. The installer has to perform a yearly maintenance. You can find the contact/helpdesk number via the user interface. Operation manual EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 19: To Display The Help Text In Case Of A Malfunction

    "8.1 To display the help text malfunction" [ 4  19]. in case of a INFORMATION When the backup heater or booster heater takes over the heat load, electricity consumption will be considerably higher. EBLA09~16DA + EDLA09~16DA Operation manual Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 20: Symptom: The System Is Making Gurgling Noises After Commissioning

    Water temperature at the water outlet of the unit. Thermostat type [3.A] Information Installer settings: Tables to Dealer information [8.3] be filled in by installer 11.1 Configuration wizard Setting Fill in… System Operation manual EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620243-1 – 2020.06...
  • Page 24 4P620243-1 0000000F 4P620243-1 2020.06 Verantwortung für Energie und Umwelt...