Field settings table

First
Second
code
code
Setting name
0
User permission level
00
User permission level
1
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (Lo_Ti)
03
Set point at high ambient temperature (Hi_Ti)
05
Weather dependent for cooling function
enable/disable
06
Low ambient temperature (Lo2_A)
07
High ambient temperature (Hi2_A)
08
Set point at low ambient temperature (Lo2_Ti)
09
Set point at high ambient temperature (Hi2_Ti)
2
Disinfection function
00
Operation interval
01
Status
02
Start time
03
Set point (only in combination with domestic hot
water tank without electrical booster heater
(EKHTS))
03
Set point (only in combination with domestic hot
water tank with built-in electrical booster heater
(EKHW*))
04
Interval (only in combination with domestic hot
water tank without electrical booster heater
(EKHTS))
04
Interval (only in combination with domestic hot
water tank with built-in electrical booster heater
(EKHW*))
3
Auto restart
00
Status
4
Space heating off temperature
00
Installation related setting
01
Installation related setting
02
Space heating off temperature
03
Installation related setting
04
Installation related setting
05
Not applicable. Do not change the default value.
06
Installation related setting
07
Installation related setting
5
Installation related setting
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
E(D/B)(H/L)Q011~016BB
Unit and options for air to water heat pump system
4PW67905-1A – 2013.02
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
3
2/3
–10
–20~5
15
10~20
40
25~55
25
25~55
0 (OFF)
0/1
20
10~25
35
25~43
22
5~22
18
5~22
Fri
Mon~Sun, All
1 (ON)
0/1
23:00
0:00~23:00
60
fixed
70
55~80
60
40~60
10
5~60
0 (ON)
0/1
35
14~35
Step
Unit
1
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1:00
hour
5
°C
5
°C
5
min
5
min
1
°C