Daikin Alterma EDHQ011AA6V3 Operation Manual

Unit for air to water heat pump system and options

Advertisement

OPERATION MANUAL

Unit for air to water heat pump system and
options
EDHQ011AA6V3
EDHQ014AA6V3
EDHQ016AA6V3
EDHQ011AA6W1
EDHQ014AA6W1
EDHQ016AA6W1
EDLQ011AA6V3
EDLQ014AA6V3
EDLQ016AA6V3
EDLQ011AA6W1
EDLQ014AA6W1
EDLQ016AA6W1
EBHQ011AA6V3
EBHQ014AA6V3
EBHQ016AA6V3
EBHQ011AA6W1
EBHQ014AA6W1
EBHQ016AA6W1
EBLQ011AA6V3
EBLQ014AA6V3
EBLQ016AA6V3
EBLQ011AA6W1
EBLQ014AA6W1
EBLQ016AA6W1

Advertisement

Table of Contents
loading

Summary of Contents for Daikin Alterma EDHQ011AA6V3

  • Page 1: Operation Manual

    OPERATION MANUAL Unit for air to water heat pump system and options EDHQ011AA6V3 EDHQ014AA6V3 EDHQ016AA6V3 EDHQ011AA6W1 EDHQ014AA6W1 EDHQ016AA6W1 EDLQ011AA6V3 EDLQ014AA6V3 EDLQ016AA6V3 EDLQ011AA6W1 EDLQ014AA6W1 EDLQ016AA6W1 EBHQ011AA6V3 EBHQ014AA6V3 EBHQ016AA6V3 EBHQ011AA6W1 EBHQ014AA6W1 EBHQ016AA6W1 EBLQ011AA6V3 EBLQ014AA6V3 EBLQ016AA6V3 EBLQ011AA6W1 EBLQ014AA6W1 EBLQ016AA6W1...
  • Page 2: Table Of Contents

    These units are used for both heating and cooling applications. The Domestic water heating operation ( w ) ..........5 units can be combined with Daikin fan coil units, floor heating Quiet mode operation ( s )..............5 applications, low temperature radiators, domestic water heating Controller operations .................
  • Page 3: Operating The Unit

    PERATING THE DIGITAL CONTROLLER PERATING THE UNIT Operating the unit comes down to operating the digital controller. Never let the digital controller get wet. This may cause an NTRODUCTION electric shock or fire. Never press the buttons of the digital controller with a hard, The AD heat pump system is designed to provide pointed object.
  • Page 4: Name And Function Of Buttons And Icons

    ACTION ICONS Name and function of buttons and icons These icons indicate the programming actions for each day of the schedule timer. OFF ICON This icon indicates that the OFF action is selected when programming the schedule timer. 10. INSPECTION REQUIRED These icons indicate that inspection is required on the installation.
  • Page 5: Setting Up The Controller

    26. DOMESTIC WATER HEATING BUTTON Setting up the controller This button enables or disables heating of the domestic water. After initial installation, the user can set the clock and day of the This button is not used when the domestic hot water tank is not week.
  • Page 6: Space Cooling Operation ( C )

    Space cooling operation ( Controller operations In this mode, cooling will be activated as required by the water temperature set point. Manual operation In manual operation, the user manually controls the settings of the NOTE The space cooling temperature set point can only installation.
  • Page 7: Schedule Timer Operation

    Selecting powerful domestic water heating operation The programmed schedule is time driven. Therefore, it Press for 5 seconds to activate powerful domestic water is essential to set the clock and the day of the week heating operation. correctly. Refer to "Setting the clock"...
  • Page 8: Programming And Consulting The Schedule Timer

    What can the schedule timer NOT do? Programming and consulting the schedule timer The schedule timer can not change the operation mode from space cooling to space heating or vice versa. Getting started How to interpret the programmed actions Programming the schedule timer is flexible (you can add, remove or To be able to understand the behaviour of your installation when the alter programmed actions whenever required) and straightforward schedule timer is enabled, it is important to keep in mind that the...
  • Page 9: Programming

    Programming Programming space cooling or space heating is carried out as follows: Programming space cooling or space heating Returning to previous steps in the programming NOTE procedure without saving modified settings is done by pressing the pr button. Use the = button to select the operation mode (cooling or heating) you want to program.
  • Page 10: Consulting Programmed Actions

    10 Press the < button for 5 seconds to store the programmed Programming quiet mode, booster heating or domestic water heating actions. If the < button is pressed when action number 3 is displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted. You automatically return to step 4.
  • Page 11: Tips And Tricks

    Tips and tricks PERATING THE REMOTE ALARM OPTION Programming the next day(s) The optional EKRP1HB remote alarm address card can be used to After confirming the programmed actions of a specific day (i.e. after remotely monitor your system. This address card offers 2 voltage free pressing the <...
  • Page 12: Detailed Description

    Save the new value by pressing the pr button. [1-03] Set point at high ambient temperature (Hi_Ti): the target outgoing water temperature when the outdoor Repeat step 2 through 4 to change other field settings as temperature equals or rises above the high ambient required.
  • Page 13 [3] Auto restart [4-04] Freeze-up protection function: avoids the freeze-up of the water piping between home and unit. In case of low When power returns after a power supply failure, the auto restart ambient temperatures it will activate the pump and in case of function reapplies the user interface settings at the time of the power low water temperatures it will additionally activate the backup supply failure.
  • Page 14 [5-04] Set point correction for domestic hot water [7] Domestic hot water step length temperature: set point correction for the desired domestic hot Applies only to installations with a domestic hot water tank. water temperature, to be applied at low outdoor temperature when space heating priority is enabled.
  • Page 15 [8] Domestic water heating mode timer NOTE Take care that [8-03] is always smaller than the Applies only to installations with a domestic hot water tank. maximum running time [8-01]. The 'domestic water heating mode timer' field settings defines the By adapting the booster heater delay time versus minimum and maximum domestic water heating times, and minimum the maximum running time, an optional balance...
  • Page 16 [C] Solar priority mode [C-00] For information concerning the EKSOLHW solar kit, refer to the installation manual of that kit. [C-01] Defines the logic of the alarm output on the EKRP1HB remote alarm input/output PCB. If [C-01]=0, the alarm output will be powered when an alarm occurs (default).
  • Page 17: Field Settings Table

    Field settings table Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit User permission level User permission level — Weather dependent set point Low ambient temperature (Lo_A) –10 –20~5 °C...
  • Page 18 Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit Solar priority mode Solar priority mode setting — Output logic of the EKRP1HB remote alarm — — input/output PCB Benefit kWh rate power supply Switching off heaters 0/1/2/3...
  • Page 19: Maintenance

    field wiring have to be carried out ISPOSAL REQUIREMENTS at regular intervals, preferably yearly. This maintenance should be carried out by your local Daikin technician. Besides keeping the remote controller clean by means of a soft damp cloth, no maintenance is required by the operator.
  • Page 20 NOTES NOTES...