OPERATION MANUAL

Unit and options for air to water
heat pump system
EDHQ011BB6V3
EDHQ014BB6V3
EDHQ016BB6V3
EDHQ011BB6W1
EDHQ014BB6W1
EDHQ016BB6W1
EDLQ011BB6V3
EDLQ014BB6V3
EDLQ016BB6V3
EDLQ011BB6W1
EDLQ014BB6W1
EDLQ016BB6W1
EBHQ011BB6V3
EBHQ014BB6V3
EBHQ016BB6V3
EBHQ011BB6W1
EBHQ014BB6W1
EBHQ016BB6W1
EBLQ011BB6V3
EBLQ014BB6V3
EBLQ016BB6V3
EBLQ011BB6W1
EBLQ014BB6W1
EBLQ016BB6W1

Advertisement

Table of Contents
loading

Summary of Contents for Daikin EDHQ011BB6V3

  • Page 1: Operation Manual

    OPERATION MANUAL Unit and options for air to water heat pump system EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1 EDLQ011BB6V3 EDLQ014BB6V3 EDLQ016BB6V3 EDLQ011BB6W1 EDLQ014BB6W1 EDLQ016BB6W1 EBHQ011BB6V3 EBHQ014BB6V3 EBHQ016BB6V3 EBHQ011BB6W1 EBHQ014BB6W1 EBHQ016BB6W1 EBLQ011BB6V3 EBLQ014BB6V3 EBLQ016BB6V3 EBLQ011BB6W1 EBLQ014BB6W1 EBLQ016BB6W1...
  • Page 2: Table Of Contents

    EDHQ011~016BB6V3 EDHQ011~016BB6W1 EDLQ011~016BB6V3 EDLQ011~016BB6W1 Operation manual Unit and options for air to water heat pump system EBHQ011~016BB6V3 EBHQ011~016BB6W1 EBLQ011~016BB6V3 EBLQ011~016BB6W1 1. D ONTENTS EFINITIONS Page 1. Definitions.................. 1 1.1. Meaning of warnings and symbols..........1 1.1. Meaning of warnings and symbols 1.2.
  • Page 3: General Safety Precautions

    The unit is used for both heating and cooling applications. The unit installed according to instructions in the documentation. can be combined with Daikin fan coil units, floor heating applications, low temperature radiators, domestic hot water tank (option) and Optional equipment: Daikin solar kit (option).
  • Page 4: Operating The Unit

    4.2. Operating the digital controller PERATING THE UNIT Operating the unit comes down to operating the digital controller. 4.1. Introduction CAUTION The heat pump system is designed to provide you a comfortable Never let the digital controller get wet. This may cause an indoor climate for many years at low energy consumption.
  • Page 5: Name And Function Of Buttons And Icons

    4.3. Name and function of buttons and icons ACTION ICONS These icons indicate the programming actions for each day of the schedule timer. OFF ICON This icon indicates that the OFF action is selected when programming the schedule timer. 10. INSPECTION REQUIRED These icons indicate that inspection is required on the installation.
  • Page 6: Setting Up The Controller

    26. DOMESTIC WATER HEATING BUTTON 34. QUIET MODE BUTTON This button enables or disables heating of the domestic water. This button enables or disables quiet mode. This button is not used when the domestic hot water tank is not If the controller is set in permission level 2 or 3 (refer to "5.
  • Page 7: Description Of The Operation Modes

    4.5. Description of the operation modes Only for [4-03]=4 or 5 In this mode, the unit will heat up the domestic hot water tank. Space heating operation (h) There are several modes for heating up the domestic water tank: In this mode, heating will be activated as required by the water Storage temperature set point.
  • Page 8: Quiet Mode Operation (S)

    Quiet mode operation ( INFORMATION In heating mode ( ) or cooling mode ( ), the water Quiet mode operation means that the unit works at reduced capacity temperature set point can also be weather dependent (icon so that the sound produced by the unit drops. This implies that the is shown).
  • Page 9: Schedule Timer Operation

    Selecting weather dependent set point operation INFORMATION Press the button to select weather dependent set point ■ Only use the button to enable or disable the operation. schedule timer. The schedule timer overrules the Icon appears on the display as well as the calculated water button.
  • Page 10: Programming And Consulting The Schedule Timer

    4.7. Programming and consulting the schedule timer INFORMATION ■ The programmed actions are not stored according to Getting started their timing but according to the time of programming. This means that the action that was programmed first Programming the schedule timer is flexible (you can add, remove or gets action number 1, even though it is executed after alter programmed actions whenever required) and straightforward other programmed action numbers.
  • Page 11: Programming

    Programming Programming space heating or domestic water heating Programming space heating or domestic water heating is carried out as follows: INFORMATION Returning to previous steps in the programming procedure without saving modified settings is done by pressing the pr button. Press the <...
  • Page 12 Programming space cooling, quiet mode, or booster heater Programming space cooling, quiet mode, or booster heater mode mode is carried out as follows: INFORMATION Returning to previous steps in the programming procedure without saving modified settings is done by pressing the pr button.
  • Page 13: Consulting Programmed Actions

    To copy programmed actions to the next day, proceed as follows: Consulting programmed actions Press the < button. Consulting space heating or domestic water heating actions The actual mode is blinking. Consulting space heating or domestic water heating is carried out as Use the pi and pj buttons to select the mode you want follows.
  • Page 14: Field Settings

    Save the new value by pressing the pr button. IELD SETTINGS Repeat step 2 through 4 to change other field settings as required. NOTICE When finished, press the z button to exit FIELD SET MODE. The default values mentioned in "Field settings table"...
  • Page 15 [1] Weather dependent set point [2] Disinfection function The weather dependent set point field settings define the parameters Applies only to installations with a domestic hot water tank. for the weather dependent operation of the unit. When weather The disinfection function disinfects the domestic hot water tank by dependent operation is active the water temperature is determined periodically heating the domestic hot water to a specific temperature.
  • Page 16 (2) or reheat is disabled (0) (>60°C). In that case Daikin suggests to install a shunt pump and a heater element parallel on the domestic hot water tank according to ■...
  • Page 17 [9-05~9-08] Automatic setback function INFORMATION Setback function provides the possibility to lower the water ■ Make sure the domestic water is only heated up to the temperature during space heating. The setback function can for domestic hot water temperature you require. instance be activated during the night because the temperature Start with a low domestic hot water storage demands during night and day are not the same.
  • Page 18 [A] Quiet mode [E] Unit information readout ■ [E-00] Readout of the software version (example: 23) This field setting allows to select the desired quiet mode. Two quiet modes are available: quiet mode A and quiet mode B. ■ [E-01] Readout of the EEPROM version (example: 23) In quiet mode A, priority is given to the unit operating quietly under all ■...
  • Page 19: Field Settings Table

    Field settings table Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit User permission level User permission level — Weather dependent set point Low ambient temperature (Lo_A) –10 –20~5 °C...
  • Page 20 Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit Installation related setting Installation related setting Installation related setting Not applicable. Do not change the default value. — —...
  • Page 21 Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit Solar kit Solar priority mode setting — Installation related setting Installation related setting Installation related setting Installation related setting Not applicable.
  • Page 22: Maintenance

    field wiring have to be carried out manual). at regular intervals, preferably yearly. This maintenance should be carried out by your local Daikin technician (see installation manual). One of the error codes appears Consult your local dealer.
  • Page 23: Disposal Requirements

    ISPOSAL REQUIREMENTS Dismantling of the unit, treatment of the refrigerant, of oil and of other parts must be done in accordance with the applicable legislation. Your product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste.
  • Page 28 *4PW67905-1 A 0000000T* 4PW67905-1A 2013.02...