Memory Switch Adjustment; Setting The Memory Switches - Muratec MFX-2550 Field Engineering Manual

Hide thumbs Also See for MFX-2550:
Table of Contents

Advertisement

3.3 Memory Switch Adjustment

3.3.1 Setting the Memory Switches

These switches are used to program internal machine parameters. The primary back up battery maintains
these settings if power are lost.
1. From standby, press <Setting>, <*>, <0>, <1>.
2. Press [Mem Switch Edit].
3. Call up the desired switch by pressing
4. Select the desired switch by pressing the box.
5. To navigate through the memory switch settings:
• The bits are ranged from 7 (left) to 0 (right).
• Press
of the cursor key to move the cursor.
or
• Press <0> or <1> on the numeric keypad, or [ ] or [ ] to change the bit value.
• Press [Enter] to save the setting of the displayed memory switch and return to the memory switch
edit screen.
• Press [Back] not to save the setting of the displayed memory switch.
6. If you want to set other memory switches, repeat step 3-5. Otherwise, proceed to step 7.
7. Press <Reset> to return the machine to ready screen.
You can confirm the initial setting of each Memory Switch by the Memory Switches List.
The memory switch List will be printed by pressing [Mem Switch Print].
or
, or by pressing the numeric keypad.
3-28

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-2570

Table of Contents