5.2.3 Scanner section

ASSY COVER CONTACT

1. Open the Cover platen [1].
2. Remove two screws [2], then remove the ASSY COVER CONTACT [3].
[ 2 ]
[ 2 ]
[ 1 ]
[ 3 ]
Caution
When removing the ASSY cover contact, be careful not to break the Glass contact.
5-57