Special Warnings and Notes
Carbon monoxide, referred to as CO, is a colorless,
odorless gas that is produced during combustion of solid
fuels. CO is toxic and can be fatal.
Even though this stove is designed to be as safe
as possible, it is recommended that you install a CO
detector. This is true for oil, gas, or wood burning
products as well.
CO is not specifically heavier or lighter than air.
Therefore, it is best to install the detector at table top level
rather than on the ceiling like a smoke detector.
Never use gasoline, lantern fuel, kerosene, charcoal
lighter fluid, or similar liquids to start or "freshen up" a
fire in this heater. Keep all such liquids well away from
the heater while it is in use.
SPECIAL NOTE:
DUE TO ASH BUILDUP, IT IS STRONGLY
RECOMMENDED TO HAVE YOUR STOVE
PROFESSIONALLY CLEANED AND SERVICED
ANNUALLY. THIS INCLUDES ALL PARTS OF
THE STOVE, AND THE VENTING SYSTEM.
Save These Instructions
CO detectors are very sensitive and may sound an
alarm for fumes other than CO or CO from sources other
than the stove such as a car or lawn mower exhaust.
If the alarm sounds
1. Increase house ventilation by opening windows or
doors.
2. Make sure the stove doors and hopper lid are closed
and latched.
3. Check stove for electrical power and normal opera-
tion.
4. Check vent for possible blockage or down-draft.
5. Check for false alarm.
NEVER CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
Installation and repair of this stove should be done
by a competent and qualified professional. We
recommend that the stove be inspected before
use and at least annually by a qualified service
person. Periodic cleaning is required throughout
the heating season and at the end of each winter
for the stove to work efficiently.
DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.
3-90-775
Pellets or Corn/Pellet Mixture Only