Clearances To Combustibles; Floor Protection; Minimum Fireplace Opening Requirements; Mantel Projections - Harman Stove Company P35i Owner's Manual

Pellet/biomass fireplace insert #1-70-774195 #1-70-774235
Table of Contents

Advertisement

B. Clearances To Combustibles -
Masonry or Manufactured Fireplace
ThE ClEARANCEs spECIfIED ARE fOR yOUR sAfETy!
ThEsE ClEARANCEs mAy ONly bE REDUCED by
mEANs AppROvED by ThE REGUlATORy AUThORITy.
D
A
F
Location
A
Insert to combustible sidewall
Surround top to face trim
B
C
Surround side to face trim
Insert top to (max) 12" mantel
D
C. Floor Protection Requirements
Location
E
Window opening to front
F
Window opening to side
Hearth extension must be of a non-combustible material. It
must extend beyond the appliance according to the mea-
surements listed.
Minimum Size Hearth Extension is 16" Deep By 32" Wide.
10
Pellets or Corn/Pellet Mixture Only
Mantel
B
C
E
Inches
Millimeters
13
0
1
12
Inches
Millimeters
6
6
D. Minimum Opening for Masonry
and Manufactured Fireplaces
Face Trim
Location
G
Minimum Width
H
Minimum Depth
I
Minimum Height #1-70-774235
I
Minimum Height #1-70-774195
E. Mantel Projections
330
0
25.4
305
152
152
The Maximum mantel depth (J) is 12 inches (305 mm) with
a minimum vertical height (K) of 12 inches (305 mm).
3-90-775
P35i Fireplace Insert
I
H
G
Inches
24
14.5
23½
19½
J
K
Save These Instructions
Millimeters
609
368
597
495

Advertisement

Table of Contents
loading

Table of Contents