Installation & Operating Manual The Harman Clarity 828i Gas Fireplace Insert “Ce manuel est disponible en Français sur demande” SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
Page 2
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Do not store or use gaso- line or other flammable vapors and liquids in the vicinity of this or any other appliance.
TABLE OF CONTENTS INTRODUCTION... 4 INSTALLATION ... 5 Clearances ... 5 Venting ... 6 Test for Flue Spillage ... 6 ASSEMBLY... 7 Connecting to a Gas Supply ... 8 Connecting the Cordset and Thermostat ... 9 Installing into a Fireplace ... 10 Air Shutter Adjustment ...
Introduction The Harman Clarity 828I Vented Gas Fireplace Insert is a listed gas-fired vented room heater tested by Intertek Testing Services/Warnock Hersey to ANSI standard Z21.88-2002, CSA2.33- M02, and CAN/CGA-2.17-M91. The installation of the Clarity Fireplace Insert must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1 —...
Clarity 828I Fireplace Insert. Clothing or other flammable materials should not be placed on or near the Clarity 828I. Surveiller les enfants. Garder les vêtements, les meubles, l'essence ou autres liquides à vapeur inflammables lin de l'appareil.
Confirm any planned changes with local building officials. VENTING Use Only Approved Venting The Clarity 828I Vented Gas Fireplace Insert is tested and listed for connection to a 4" (100 mm) listed Class B venting system. If the unit is installed to vent through an approved...
Assembly The Clarity 828I Fireplace Insert comes with the log set packed inside the firebox. The three trim panels and two wing brackets are packed together in a separate carton. NOTE: The wing brackets must go on before the door.
Log Positions When Assembled Install the center log so that it goes all the way to the back and is centered. When properly posi- tioned, there should be an even gap along the front of the center burner in the cavity in the log. A small portion of the log support frame will be revealed.
BEFORE OPERATING Gas Pressure Requirements Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient performance of this appliance. Make sure that the plumber or gas supplier checks the gas sup- ply line and gas pressure at installation.
INTO THE FIREPLACE The Clarity Fireplace Insert has an integrated draft hood, so a separate draft hood is not re- quired. Some fireplace openings may be large enough to connect the draft hood to the venting after the unit has been moved to its final position. Some openings will be too small and will require that the draft hood first be connected to the venting, and then guided into position on the top of the insert as the...
Swing-out Label with lighting instructions Flame Adjustment Levers Use a glove to avoid contact if hot. For best results when fine-tuning the flame picture, initially leave the middle lever unchanged from its factory set- ting. Move the other two levers as needed to increase or decrease the brightness and length of the flame: moving left will increase the flame;...
Any access panels that are removed for servicing must be replaced prior to operating the Clarity 828I Vented Gas Fireplace Insert. REMOVING THE GLASS DOOR AND TRIM PANELS To gain access to the latches that secure the door, frist remove the two side trim panels.
confirm that there is no blockage and that the system is in good repair. Directions for conducting a flue spillage test may be found on page 6. The vent manufacturer's instructions may provide specific suggestions or details on vent inspection. Any sections that are taken apart for the inspection must be reassembled and sealed as required.
Arch Frame Right Trim Panel Right Wing Optional Sunrise Gold Frame Valve Door Top Wing Top Trim Panel Screw Ait Inlet Grill (Remove to connect Blower Speed Switch thermostat) Flame Adjusters Valve Thermostat Right Trim Panel Right Wing Cord Channel...
Appendix A: Fuel Conversion CONVERTING THE CLARITY FIREPLACE INSERT FROM ONE GAS TO ANOTHER IN THE FIELD NOTE: THE CONVERSION SHALL BE CAR- RIED OUT IN ACCORDANCE WITH THE RE- QUIREMENTS OF THE PROVINCIAL OR LO- CAL AUTHORITIES HAVING JURISDICTION AND IN ACC OR DANC E WITH R EQUIRE- MENTS OF THE CURRENT EDITION OF THE NATIONAL FUEL GAS CODE, ANSI Z223.1 or...
Appendix B: For U.S. installations, the Clarity Fireplace Insert is approved for elevations up to 2000 feet using the factory-installed burner injectors. At elevations above 2000 feet, U.S. codes require a decrease in the input rating by changing the burner injectors to a smaller size.
Appendix C: To change the orifices, such as when derating for altitude, follow these steps. 1. Remove the side trim panels according to the directions on page 12 to gain access to the levers that secure the glass door, then remove the glass door according to the directions on page 7.
Appendix D: Low Voltage Wiring Diagram 120 Volt Wiring Diagram The Clarity Fireplace Insert, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current edition of the National Electrical Code, ANSI/NFPA 70 in the United States or the current Canadian Electrical Code CSA 22.1 in Canada.
Parts List The following replacement parts for your Harman Clarity Fireplace Insert are available from your Har- man dealer. 1. Pilot 3-40-08229 Pilot 3-40-08230 2. Thermopile 3-20-08219 3. Pilot Tube 2-00-446118 4. Thermocouple 3-40-08228 5. Piezo Ignitor 3-40-08220 6. Ignitor Cable 3-40-08231 7.
Specifications Tested to ANSI Z21.88-2002, CSA 2.33-M02, CAN/CGA 2.17-M91. Input Rating (Btu/hr) (0-1370 m) Min. Input Rating (Btu/hr) (0-1370 m) Injector Sizes (DMS) (front/center/rear (0-1370 m) Manifold Pressure (in w.c./kPa) Minimum Manifold Pressure (in w.c./kPa) Minimum Inlet Pressure (in w.c./kPa) Maximum Output (Btu/hr) (0-1370 m) AFUE (seasonal efficiency;...
Page 23
MERCHANTABILITY, OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. No employee, agent, dealer, or other person is authorized to give any warranty on behalf of Harman Stove Company. This warranty does not apply if the product has been altered in any way after leaving the factory. Harman Stove Company and its agents assume no liability for “resultant damages of any kind”...