Read And Write Frame Error Counter Page (34H & 35H) - Sony SDX-1100V/R User Manual

Ait-5
Table of Contents

Advertisement

LOG SENSE
All board revision number is 8 bytes long and has a following format:
Table 6-29: All Board Revision Number Parameter Format
Each Mechanism Error Event is 24 bytes long and has following format:
Byte offset
0-3
4-7
6.6.10. Read and Write Frame Error Counter Page (34h & 35h)
The Read and Write Error Counter Page has the following format. All fields in these logs are initialized to ZERO in
the following circumstances:
At Power On
After a cassette unloading
After a user sends a request for initialization through Log Select
Bit
7
Byte
0
Page Code (34h Write Frame Error Counters, 35h Read Frame Error Counters)
1
2
(MSB)
3
Error Counter Descriptors
Bit
7
Byte
0
(MSB)
1
2
DU (0)
3
4
(MSB)
7
Parameter Code: This identifies which parameter of data is being transferred. The following codes are supported
for each Error Counter Page.
SONY AIT-5 drive SDX-1100V series Ver.1.0
0
Set revision
1
2
Board revision
3
4
Mechanism revision
5
6
RF revision
7
Table 6-30: Mechanism Error Event Format
Drum revolution minutes
Error code
Table 6-31: Read and Write Frame Error Counter Page
6
5
Page Length (88h)
6
5
Parameter Code
DS (1)
TSD (0)
ETC (0)
Parameter Length (4)
Parameter Value
Meaning
4
3
2
Reserved
4
3
2
TMC (0)
6.Command Specification
1
0
(LSB)
1
0
(LSB)
LBIN (0)
LP (0)
(LSB)
6-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdx-1100v

Table of Contents