Altitude; Suspended Particulate; Vibration; Shock - Sony SDX-1100V/R User Manual

Ait-5
Table of Contents

Advertisement

2.2.2. Altitude

Operating

2.2.3. Suspended Particulate

Operating

2.2.4. Vibration

Operating
Non-operating

2.2.5. Shock

Operating
Non-operating

2.2.6. Acoustic Noise

The ambient noise level is no greater than 25 dB (A). The sound-meter on (A) scale is located 1m in front of the
center of the drive front panel. (A): A curve weight
Streaming Write/Read
Insert/Eject

2.2.7. EMC

EMI/EMS
Radiated Emissions /
Conducted noise
Emissions
EMS
ESD
(Front Panel Only,
integrated product)

2.2.8. Orientation

The SDX-1100V can be installed in three different mounting positions as shown in the figure below. Each position
has a maximum tolerance of ± 10 degrees.
SONY AIT-5 drive SDX-1100V series Ver.1.0
0 to 10,000 feet
Less than 150 microgram/m
Based Sampling period 24 hours
Swept Sine 5 to 500Hz, @0.25G Peak 1 Octave/min.
3 axis, 3 directions
Swept Sine 5 to 500Hz, @ 0.5G Peak 1 Octave/min.
3 axis, 3 directions
No Data Loss
Half Sine
Performance
5 G Peak 3 ms
3 axes, 3 directions
*Interval 10 seconds
No Device Damage
Half Sine
90 G Peak 3 ms
(30 G Peak 11 ms)
3 axes, 3 directions
* Interval 10 seconds
35dB(A)
60dB(A)
EN 55022 / 94 + EN 55022 A1 / 95 class B
Discharge Voltage
Less than 15kV: No operation failure
Less than 20kV: No drive damage
3