7

Specifications

Voltage
Frequency
Power
Requirements
Input current
Voltage fluctuation
Ambient temperature
Operating
Relative humidity
Environment
Air pressure
Ambient temperature
Storage
Relative humidity
Environment
Air pressure
Lamp
Average life span
Illumination
Color temperature
Brightness control
PENTAX color video
endoscopes
Scope Compatibility
PENTAX fiberscopes
Air pump system
Pressure setting at flow rate at 0
Air Feed System
Standard air feed volume at inlet
of water bottle
Water bottle assembly
Water Feed System
pressurized by pump
Automatic
Brightness
Control System
Manual
Color System
Color correction
Freeze Function
Cooling
Digital output
Video Signals
Analog output
Remote
Control Signals
Keyboard
Type of protection against
electric shock
Degree of protection against
Classification as
electric shock
Electro Medical
Equipment
Degree of explosion proofing
Electro Magnetic
Designed in accordance with
Compatibility
Compliance
Designed in accordance with
Size
Excluding protrusions
Weight
Main Body
120VAC (NTSC MODEL)
2.8 A
This processor can be used with
- PENTAX color video endoscopes (K-series) except 30K, 40K,
70CIMK/CIFK/CILK (Confocal Endomicroscopes) and 70UK/
UTK/URK (Ultrasound Endoscopes) series
NTSC MODEL
This processor can be used with
- PENTAX fiberscopes with use of PENTAX video adapter
module PVK-1070 and PVK-1070Z
Live video is displayed in a sub-image while freeze mode is
activated.
SERIAL
RGB
Y/C
Composite
Y
Type BF (Body Floating), using insulated endoscope.
Use on a heart is prohibited.
Do not use in potentially flammable surroundings.*
* The processor is not suitable for use in a mixture of air and
flammable anesthetic gas or a mixture of oxygen/nitrous oxide and
flammable anesthetic gas.
EN60601-1-2 (2001) + A1 (2006) for EU
IEC60601-1-2 (2001) + A1 (2004) for other countries
UL60601-1
Width 380 mm × Height 155 mm × Depth 430 mm
230VAC (PAL MODEL)
50 - 60 Hz
±10%
10 - 40°C
30 - 85% (with no condensation)
700 - 1060 hPa
–20 - 60°C
0 - 85% (with no condensation)
700 - 1060 hPa
150-W twin halogen lamp
50 h
3,400 K
Selection: Automatic/Manual
DC Diaphragm
45 - 72 KPa (maximum pressure)
Low: 2.0 - 4.0 L/min
High: 4.1 - 7.0 L/min
Bottle capacity = 250 ml
Selection: Average / Peak
±5 step adjustment
Red/Blue ±5 step adjustment
Forced air cooling
1 set
1 set
2 sets
1 set
1 set
2 sets
1 set
Class I equipment, 3 prong plug
11.0 kg
Specifications
1.4 A
PAL MODEL
1 set
IEC60601-1
50