TrOuBLEShOOTiNg guidE

wArNiNg:
Always turn off power at the main electrical service panel when servicing your air bath.
SymPTOmS
Air Bath does not operate.
Blower turns off by itself or
before time elapses.
circuit breaker trips repeatedly.
Blower does not manually shut off.
Air Bath does not function
properly while in the pulse or
wave modes.
rePLAceMent PArts Order MAP
4) ANd 14)
CONTrOL
PANEL
5) LighT wALL
FiTTiNg
7) ChrOmAThErAPy LighT
28
POSSiBLE PrOBLEmS
1)
no power to Air Bath unit.
2)
Blower control Box is not plugged in.
3)
control Panel connector to controller
box is disconnected.
4)
Blower Motor is disconnected from
control box.
1)
Blower motor overheated and thermal
protection device has deactivated motor
(possibly low voltage).
2)
gFci tripped.
1)
defective breaker.
2)
short circuit between bath and
breaker box.
3)
Other items are connected to the
same circuit.
1)
defective control panel.
2)
defective control box.
1)
speed of air setting is set too low.
SErENiTy aIr BatHs
3) ChECK
VALVE
(ONE wAy
VALVE)
SuggESTEd SOLuTiONS
1)
reset circuit breakers and gFci if tripped.
check fuses and replace if bad.
2)
Make sure plug is fully inserted into the outlet.
3)
check and reconnect if needed.
4)
Plug blower into control box.
1)
check that the blower has sufficient
ventilation and that the intake to the blower is
not blocked. clear and allow motor to cool
down. (check service and wire size.)
2)
refer to installer/dealer.
1)
change out breaker.
2)
refer to installer/dealer.
3)
refer to installer/dealer.
1)
refer to installer/dealer. replace control panel.
2)
refer to installer/dealer. replace control box.
1)
change the air speed setting to a mid-range
setting before switching to wave or pulse
modes.
2) CONTrOL BOx