iNSTALLATiON iNSTruCTiONS
SErENiTy STudiO 17, 23, 24, 25 ANd 26 iNSTALLATiON (CONT):
2. drill 2" holes for the drain and air passage holes. to
prevent the bath from moving sideways, secure the
two anchoring pins (3/8" x 3" lag bolts) to the floor (see
diagram 10F). Leave the lag bolts 1 1/2" above floor.
wipe off the marker tracings.
3. install the overflow and drain on the bath. cut pipes to
desired length prior to assembly (see diagram 10g). glue
the first pipe section (PVc 1 1/2") of the air passage to
go under the floor and make sure pins are lined up with
holes in tub. Apply a silicone seal under the rim of the
base and lay the bath down putting the pipes through
the floor. immediately remove any excess silicone.

VAriABLE SPEEd Air BLOwEr rEmOTE mOuNTiNg FOr FrEESTANdiNg mOdELS:

dESigNATiNg A rEmOTE LOCATiON:
the designated location for the blower must not require more than 15 feet of pipe and 6 directional changes. choose
a place as close to the bath as possible to make sure that the system works properly. the chosen place must not be
cluttered and/or dusty and must allow for sufficient air circulation. the air around the blower should be approximately
72°F (20°c) for optimal performance. the blower and control box must be accessible at all times. see pages 18-19
for installation diagrams.
iNSTALLiNg ThE BLOwEr iN A rEmOTE LOCATiON:
the blower will come attached to the one way check valve, make sure the arrow on the valve is pointing away from the
blower.
the blower can be installed horizontally or vertically. the blower intake may be installed up or down. use PVc 1½" pipe
and adapters only. whenever possible, use two 45° elbows instead of one 90° elbow to change the direction of your
pipe. glue all pipe connections along the extension you have added.
the blower should be 6" off the floor or ceiling and the air intake end of the blower should be at least 4" from any walls
or joists. the location of the blower should not be air tight; a gap of 1" is recommended for good air circulation. to
reduce heat loss, insulate the pipe.
mOuNTiNg ThE CONTrOL BOx:
Mount the control box close to the blower and the Ac outlet. (120 vac minimum 15 amp dedicated gFci protected).
You will be able to mount both the infrared sensor and key pad (attach by pressure sensitive tape on back of keypad) or
you may want to mount only the infrared sensor. when mounting the infrared sensor be sure there are no obstructions
between the sensor and the tub. Both cables are 25 feet long.
At the control box, plug the cord from the blower into the control box, then plug in the infrared sensor cord and the key pad
cord, if it is going to be used. then plug in the three prong plug to a 120 vac minimum 15 amp dedicated gFci protected
outlet. see control box wiring diagrams on pages 18, 19 and 21.
Aim remote control at the infrared sensor and check. (see remote control Operation on pages 24-25.)
NOTE: A red light will flash rapidly after pushing any button on the remote control. if light does not flash when a key
is depressed, replace the batteries.