Install The Log Set; Install Remote Switch (Millivolt Valve Only); Fan Wiring Diagram - Vermont Castings UVS27R Owner's Manual

Vent free gas heater
Table of Contents

Advertisement

Fig. 9 Attach snapstat to inner shroud.
Control Panel
Retaining Nut
Control Knob
Fig. 10 Attach rheostat to control panel.
MOTOR
BLK
Fig. 11 Fan wiring diagram.

Install remote switch (Millivolt valve only)

• Thread wire through the electrical knockout
located on either side of the fireplace. Do not cut the
wire or insulation on metal edges. Ensure that the
wire is protected. Run the other end to a conve-
niently located wall receptacle box.
• Attach the wire to the switch and install the
switchinto the receptacle box. Attach the cover plate
to the switch.
• Connect the remaining ends of the optional switch
to the valve at Terminal 3 and the tab connector on
Terminal 1. (Fig. 12)
NOTE: If any of the original wire as supplied with the
appliance must be replaced, it must be replaced with a
wire of at least 105 F temperature rating.
Connect the gas supply line to the flex or hard pipe
from the control valve as required by local codes.
ST346
Rheostat
ST347
BLK
SNAPSTAT
WHT
ON/OFF
RHEOSTAT
ST236
Vermont Castings UVS27
To Optional GWSK
Wall Switch
1
T'STAT
OFF
2
3
ON
TH Terminal
Fig. 12 Connecting wall switch to valve terminals.

Install the Log Set

• Remove the logs from their packaging, and inspect
each piece for damage.
NOT INSTALL DAMAGED LOGS.
• Install the rear log A, by engaging it with the pins
on the sheet metal shelf at the back of the firebox.
(Fig. 13)
• Install the left and right middle logs, B and C, by
engaging holes on their bottoms with pins on the
burner brackets. (Fig. 13)
• Press the burner assembly fully to the rear, by
hand. Place the two front ember log sections, D and
E, in the slot at the front of the firebox.
• Loosely sprinkle the lava rocks directly on top of
the burner between the ember logs and the middle
logs. Do not place any ember material behind the
middle logs. (Fig. 14)
• Engage the socket in the upper right log, F, with the
pin on the right middle log C, as shown in Figure 15.
The back end of log F should rest on log A and touch
the back of the firebox.
• Engage the socket in the bottom of upper left log,
G, with the pin on the left middle log B, as shown in
Figure 15. Rest the back end of log G on top of log
F. Adjust logs F and G to contact the back wall of
the firebox.
B
Fig. 13 Install the back, left and right logs.
TP/TH Terminal
OFF
ST349
DO
(Fig. 14)
A
C
ST109
11
m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uvs27m

Table of Contents